HALOGEN
High I2t Chip™ Fuses
CC12H Series
HF
Pb
FREE
Dimensions - mm (in)
Drawing Not to Scale
0.51 +/- 0.25 typ.
(0.02 +/- 0.01)
0.51 +/- 0.25 typ.
(0.02 +/- 0.01)
1.6 +/- 0.2 typ.
(0.063 +/- 0.008)
Surface Mount Device
Top View
Side View
Description
• High I2t 1206 footprint surface mount fuse
• High inrush withstand capability
0.6 + 0.2, -0.15
(0.024 +0.008, -0.006)
End View
• Excellent temperature and cycling characteristics
• RoHS compliant, and lead free and halogen free construction
• Compatible with solder reflow and wave solder
1.6 +/- 0.2
3.2 +/- 0.2
(0.063 +/- 0.008)
Electrical Characteristics
(0.126 + /- 0.008)
Amp Rating
1-5A
% of Amp Rating
Opening Time
4 Hours Minimum
1-60 Seconds
1.52 (0.06)
Pad Layout - mm (in)
100%
200%
1-3A
1-5A
1-5A
1-5A
250%
300%
1000%
5 Seconds Maximum
0.1-3 Seconds
0.2-20mS
2.03 (0.08)
Agency Information
1.52 (0.06)
•
Recognition File number: E19180 (1- 5A)
Environmental Data
Soldering Method
• Thermal Shock: MIL-STD-202, Method 107, Test Condition B
• Vibration: MIL-STD-202, Method 204, Test Condition C
• Moisture Resistance: MIL-STD-202, Method 106, 50 day cycle
• Solderability: ANSI/J-STD-002, Test B
• Normal ambient temperature: 23°C
• Operating temperature range -40°C to 125°C
• Wave Solder Immersion: 260°C, 10 seconds maximum.
• Solder Reflow: 260°C, 30 seconds maximum.
Packaging and Ordering
• 3000 fuses on 8mm tape-and-reel on a 7 inch (178mm) reel per EIA
Standard 481. Specify Catalog Symbol and package code suffix “-TR”
(e.g., CC12H1A-TR)
Specifications
Catalog
Current
Amp Rating
Voltage
Interrupting
Resistance
(Ω)** Typical
0.35
Typical Melt
Typical Voltage
2
Symbol
Rating (Amps)
Mark
Rating (Vdc)
Rating* (Amps)
(I t)† DC
Drop (mV)‡
CC12H1A
CC12H1.5A
CC12H2A
CC12H2.5A
CC12H3A
CC12H3.5A
CC12H4A
CC12H4.5A
CC12H5A
1
1.5
2
2.5
3
3.5
4
H
K
N
O
P
R
S
X
T
63
63
63
63
63
63
63
32
32
50
50
0.18
0.4
1.1
1.7
2.2
2.7
3.2
4.2
6.0
490
355
305
240
185
180
169
160
0.178
0.10
0.07
0.045
0.034
0.03
0.025
0.021
50
50
50
50
50
100
100
4.5
5
140
*
DC Interrupting Rating (Measured at rated voltage, time constant of less than 50 microseconds, battery source)
** DC Cold Resistance (Measured at 10% of rated current)
†
‡
Typical Melting I2t (Measured with a battery bank at rated DC voltage, 10x-rated current, not to exceed IR, time constant of calibrated circuit less than 50 microseconds)
Typical Voltage Drop (Measured at rated current after temperature stabilizes)
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated ambient temperatures.
0210 BU-SB10139
Page 1 of 2
Data Sheet 4309