CAR1212FP Series
1200 Watt +12V Front End Power Supply
Features:
∎ Measures 11.20 x 4.00 x 1.65” / 284.5 x 101.6 x 41.9mm
∎ 12V Power for Powering Non-Isolated POL Converters
∎ Hot Swap / N+1 Redundant
∎ Active Single Wire Current Sharing
∎ Remote On/Off Control
∎ International Safety Approvals - UL, CSA, CE Mark (LVD) TUV
KEY MARKETS & APPLICATIONS
FEATURES
BENEFITS
High Power Density 16W/in3
1U High Form Factor
5VSB Standby Voltage
Minimizes space within your system
Supports low profile applications
∎ Distributed Power ∎ Blade Servers
∎ Mid-End Servers
∎ Network Equipment
∎ Network Attached Storage
∎ Storage Area Networks
Provides voltage source for housekeeping and monitoring circuitry
I 2C Digital Control & Monitoring Cost effective power scalability
SPECIFICATIONS
Input Voltage Range
Input Current Maximum
Inrush Current
Input Protection
Power Factor
1200 Watt +12V Front End Power Supply
85-264 VAC, 47-63 Hz
12A @ 100VAC, 8.1A @ 180 VAC, full Load
35A max. cold start (per ETS 300 132-1 and bellcore specifications)
Single Fused (Line) 20 Amp / 250 VAC Type 3AB Axial
0.99 typical complies with IEC555, EN60555-2, EN61000-3-2
Efficiency
Output Power
Output Voltage Range
Output Current
Voltage Programming
Standby Bias Voltage
Voltage Regulation
Ouput Ripple & Noise
Transient Response
Switching Frequency
Hold-Up Time
89% typical at 230 VAC Full Load Operation, 85% Typical @ 90 VAC Full Load Operation
1200W at High Line Operation (230 VAC), Derate to 1000W
+12 VDC (±5%)
100A @ +12 VDC for High Line Operation (230 VAC), reduced to 83.5 A at Low Line Operation (110 VAC)
±5% of Vout nominal. Analog input signal. 11.4V + (Vprog x 0.3V) where Vprog = 0V to 4V
5VSB@500mA, reference to +12VDC Return
±2% of Vnom for any combination of line, load and temperature
ETS300 132-2, 32dBnrc. Bandwidth: 25Hz - 20kHz. 2mVrms pk-pk with 0.1µF ceramic and 10µF electrolytics caps
5% max deviation Recovery time 300µs @ 50% load step and di/dt < 1A/µs
400kHz (output)
20ms at 1200W (typical) @ 180VAC
Remote On/Off
ON if >3V or open; OFF if <1V (max. sink 1mA) Open collector type
110-135% of Iout Nominal
Self protected with auto recovery
+14.5-15.5 VDC max, latched. Reset condition by recycling AC Input or toggling remote on/off
-10°C to +70°C. power derating above 55°C at 2.5% per °C
Non latching; protection active at 110°C internal temperature, restart at 95°C (typical)
FCC-B & EN55022-B with specified filter, GR-1089-CORE
Green = AC OK & DC OK, Red = Fault
Current Limit Protection
Short Circuit Protection
Over Voltage Protection
Operating Temperature
Over Temperature Protection
EMI
LED Indicators
Analog Status & Control
Voltage Programming (V Prog), Load sharing (I Share), Remote ON/OFF, Current Monitor (I Monitor),, Over temperature
(Temp Warning), Fault, PS Present, Module Enable
Digital Status & Control
Shock & Vibration
Dimensions
I 2C Option, see detailed specification for details
IEC68-2-27, MIL-STD-810E, Telecordia GR-63-CORE
11.20 x 4.00 x 1.65” / 284.5 x 101.6 x 41.9mm
3.0 lbs
Weight
Safety Approvals
Options
IEC 950 per EN60950, UL60950, CSA 22.2-950, CE Mark (LVD) TUV
I2C Signals, Bezel
www.lineagepower.com/oem
rev 100506
Lineage Power
Lineage Power
Lineage Power (China)
3000 Skyline Dr.
Mesquite, TX 75149
Phone: (972) 284-2000
2841 Dow Avenue
Tustin, CA 92780 USA
Phone: (714) 544-6665
1353 Chenqiao Road, Shanghai Sengpu Industrial Park
Shanghai, 201401 China
Phone: 021 6710 8910