300A AC Current Clamp-on

CA310 数据手册

 浏览型号CA310的Datasheet PDF文件第2页 
User’s Guide  
300 AMP AC CLAMP ADAPTOR  
OUTPUT VOLTAGE: 1mV AC Per 1A AC  
CATII 600V  
CA300  
Model CA310  
300A AC Current Clamp-on  
MultiMeter Adaptor  
Introduction  
Congratulations on your purchase of the Extech CA310 300 Amp AC Clamp-On MultiMeter  
Adaptor. With this clamp adaptor an AC current can be safely measured by simply clamping  
around a single conductor. The adaptor outputs an AC mV signal that is proportional to the  
measured AC current. The DMM mV reading (times 10) is equivalent to the value of the AC  
current. Careful use of this device will provide years of reliable service.  
Specifications  
Sensor type  
Induction coil  
Measurement Range  
Adaptor Output  
0.1 to 300 Amps AC  
10mV AC output to DMM per 1A AC measurement  
Frequency range  
Working voltage  
Maximum output impedance  
Accuracy  
50/60Hz  
600V CAT II (IEC 1010-1)  
45  
± (3.0% + 10mV) for readings less than 50A  
± (2.0% + 5mV) for readings greater than 50A  
Temperature coefficient  
Jaw size  
Operating Conditions  
Dimensions/Weight  
0.2 times the specified accuracy per oC < 18oC or > 28oC  
1.2" (30mm)  
32 to 122oF (0 to 50oC) < 80% RH  
3.2 x 6.1 x 1.4" (80 x 156 x 35mm); 7.8 oz. (220g)  
NOTE: Accuracy is specified for a period of one year for ambient conditions 64oF to 84oF  
(18oC to 28oC) < 80% RH.  
Safety  
Safety Symbols  
This symbol, adjacent to another symbol or terminal, indicates the user must  
refer to the manual for further information.  
This symbol indicates that double insulation is used.  
WARNING: This indicates that a potentially hazardous condition which, if not avoided,  
could result in death or serious injury.  
Safety Precautions  
1. WARNING: Improper use of this meter can cause damage, shock, injury or death.  
Read and understand this manual before operating the meter.  
2. Inspect the condition of the test leads and the meter itself for any damage before  
operating the meter. Repair or replace any damage before use.  
3. Do not use on non-insulated conductors at voltages greater than 250VAC rms or DC.  

与CA310相关器件

型号 品牌 描述 获取价格 数据表
CA-310 ETC Aluminium enclosures CA series

获取价格

CA3100 HARRIS 38MHz, Operational Amplifier

获取价格

CA3100 INTERSIL 38MHz, Operational Amplifier

获取价格

CA3100A ITT ITT Cannon is the foremost manufac-turer of MS and MS type connectors with the widest rang

获取价格

CA3100A18-8P ITT CA/MS A and B

获取价格

CA3100A18-8S ITT CA/MS A and B

获取价格