Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, 900 Series, Encapsulated,  
AC Type, X1 440 VAC/Y2 300 VAC (Industrial Grade)  
Overview  
KEMET’s 900 Series encapsulated radial leaded ceramic  
disc capacitors are specifically designed for interference-  
suppression AC line filtering applications. Having interna-  
tionally recognized safety certifications, these capacitors  
are well-suited for applications that require keeping poten-  
tially disruptive or damaging line transients and EMI out  
of susceptible equipment. They are also an ideal solution  
in situations where there is a need to suppress line distur-  
bances at the source.  
With a working voltage of 440 VAC in line-to-line (Class X)  
and 300 VAC in line-to-ground (Class Y) applications, these  
safety capacitors meet the impulse test criteria outlined in  
IEC Standard 60384. Meeting subclass X1 and Y2 require-  
ments, these devices are certified to withstand impulses up  
to 4 KV (X1) and 5 KV (Y2) respectively. These encapsulated  
devices also meet the flame test requirements outlined in UL  
Standard 94V–0.  
Safety Certified Capacitors are classified as either X and/or  
Y capacitors. Class X capacitors are primarily used in line-to-  
line (across-the-line) applications. In this application there is  
no danger of electric shock to humans should the capacitor  
fail, but could result in a risk of fire. The class Y capacitor is  
primarily used in line-to-ground (line by-pass) applications. In  
this application, failure of the capacitor could lead to danger  
of electric shock.  
Click image above for interactive 3D content  
Open PDF in Adobe Reader for full functionality  
Ordering Information  
C9  
7
1
U
472  
M
Z
W
D
A
A
7317  
Ceramic  
Series  
Body  
Diameter  
Lead  
Spacing1,2,4  
Capacitance Capacitance Rated Dielectric/  
Lead  
Config.1,3,4  
Failure Packaging  
Spec.  
Design  
Code (pF)  
Tolerance  
Voltage Temp. Char.  
Rate  
(C-Spec)  
C9 =  
0 = 7.0 mm  
7 = 7.5 mm  
1 = 10.0  
mm  
U =  
Two  
J = ±5%  
Z = X1 S = SL  
440 VAC Y = Y5P  
/Y2 300 W = Y5U  
D = A = Straight  
Disc B = Vertical  
Kink  
A =  
N/A  
See  
"Packaging  
C-Spec  
Ordering  
Options  
Table"  
Ceramic 1 = 8.0 mm  
900 2 = 9.0 mm  
Series 3 = 10.0 mm  
4 = 11.0 mm  
Safety significant K = ±10%  
digits and M = ±20%  
number of  
VAC  
V = Y5V  
C = Outside  
Kink  
D = Inside  
Kink  
zeroes  
6 = 13.0 mm  
8 = 15.0 mm  
below  
1 Due to a high risk of arcing, "Inside Kink" lead configuration cannot be combined with the 5 mm lead spacing option. The "Inside Kink" option is only  
available on capacitors with lead spacing of 7.5 mm or greater. A potential for arcing may exist when combining the "Inside Kink" lead configuration  
with a 7.5mm lead spacing option, especially in high humidity environments and/or when exposure to voltages and transients may impact creepage and  
clearance requirements.  
2 Capacitor body diameter will limit available lead spacing and packaging options. See "Dimensions" and "Product Ordering Codes and Ratings" sections  
of this document to determine availability.  
3 "Vertical Kink", "Outside Kink" and "Inside Kink" lead configurations cannot be combined with the bulk/20 mm lead length option (WL20). 20 mm lead  
length is only available on capacitors with straight leads (lead configuration ordering code "A"). For nonstandard lead length inquiries, please contact  
KEMET.  
4 Bulk packaging lead length availability is dependent upon "Lead Configuration" and "Lead Spacing." See "Dimensions" section of this document to  
verify availability of a specific lead length option. For nonstandard lead length inquiries, please contact KEMET.  
One world. One KEMET  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1065_X1_440 VAC_Y2_300 VAC • 1/13/2017  
1

与C961U472MZSDDA7317相关器件

型号 品牌 获取价格 描述 数据表
C961U472MZVDAA7317 KEMET

获取价格

Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Indu
C961U472MZVDBA7317 KEMET

获取价格

Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Indu
C961U472MZVDCA7317 KEMET

获取价格

Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Indu
C961U472MZVDDA7317 KEMET

获取价格

Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Indu
C961U472MZWDAA7317 KEMET

获取价格

Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Indu
C961U472MZWDBA7317 KEMET

获取价格

Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Indu
C961U472MZWDBA7317_17 KEMET

获取价格

Ceramic, Safety, C900_Z, 4700 pF, 20%, Y5U, Lead Spacing = 10mm
C961U472MZWDCA7317 KEMET

获取价格

Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Indu
C961U472MZWDDA7317 KEMET

获取价格

Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Indu
C961U472MZYDAA7317 KEMET

获取价格

Safety Standard Recognized, 900 Series, Encapsulated, AC Type, X1 440 VAC/Y2 300 VAC (Indu