5秒后页面跳转
C10083CAH PDF预览

C10083CAH

更新时间: 2024-01-28 11:16:48
品牌 Logo 应用领域
HAMAMATSU 传感器图像传感器
页数 文件大小 规格书
4页 300K
描述
Mini-spectrometer TM series High sensitivity type (integrated with back-thinned type CCD image sensor)

C10083CAH 技术参数

生命周期:ActiveReach Compliance Code:unknown
风险等级:5.84

C10083CAH 数据手册

 浏览型号C10083CAH的Datasheet PDF文件第2页浏览型号C10083CAH的Datasheet PDF文件第3页浏览型号C10083CAH的Datasheet PDF文件第4页 
M O D U L E  
Mini-spectrometer TM series  
C10082CA, C10082CAH, C10083CA, C10083CAH  
High sensitivity type (integrated with back-thinned type CCD image sensor)  
TM series mini-spectrometers are polychromators integrated with optical elements, an image sensor and a driver circuit. Light to be measured is  
guided into the entrance port of TM series through an optical fiber and the spectrum measured with the built-in image sensor is output from the  
USB port to a PC for data acquisition. They are high sensitivity mini-spectrometers employing a back-thinned type CCD image sensor. Their  
sensitivity is about two orders of magnitudes higher than CMOS type making TM series even more ideal for low-light-level measurement.  
C10082CAH and C10083CAH are high resolution type (spectral resolution: 1 nm Typ.).  
Mini-spectrometer TM series comes supplied with free sample software that allows setting measurement conditions, acquiring and saving data,  
and displaying graphs. Driver software and DLL are also supplied as accessory items to allow the users to configure their own measurement  
software.  
Features  
Applications  
Integrated with back-thinned type CCD image sensor:  
Sensitivity is about two orders of magnitude higher than  
CMOS type  
Low-light-level measurement such as fluorescence measurement  
Semiconductor process control  
Evaluation of light source characteristics such as LED  
High resolution: 1 nm (C10082CAH, C10083CAH)  
High throughput due to transmission grating made of quartz  
Highly accurate optical characteristics  
Comparison of CCD type  
and CMOS type  
Wide spectral response range  
Easy to install into equipment  
Wavelength conversion factor *1 is recorded in internal memory  
Output comparison (relative value)  
C10082CA  
C10082CAH  
C10082MD  
C10083CA  
C10083CAH  
C10083MD  
O ptical characteristics  
TM -UV/VIS-C CD  
C10082C A C10082CA H C10083C A C10083CA H  
200 to 800 320 to 1000  
TM-VIS/NIR-CC D  
Param eter  
Unit  
nm  
(Typ. Ta=25 ˚C)  
101  
100  
Spectral response range  
Spectral resolution Max.  
(Spectral response half width) *2  
W avelength reproducibility *5  
W avelength tem perature  
4
6
1 *3 8 *4 1 *3,  
*
nm  
0.2  
nm  
10-1  
10-2  
10-3  
n m/° C  
dB  
0.04  
dependence  
6
Spectral stray light *2,  
*
-33  
-30  
Electrical characteristics  
Param eter  
A/D conversion  
Integration tim e  
Interface  
USB bus power  
current consum ption  
External power supply  
Specification  
16  
10 to 10000  
USB1.1  
Unit  
bit  
m s  
-
10-4  
10-5  
100  
5
m A  
V
200 300 400 500 600 700 800 900 1000  
WAVELENGTH (nm)  
G eneral ratings / Absolute m axim um ratings  
Param eter Specification  
Dim ensions  
Unit  
m m  
* A/D count when constant light level enters fiber.  
95 (W ) × 92 (D) × 76 (H)  
KACCB0168EA  
Back-thinned type CCD im age sensor  
Im age sensor  
-
Measurable optical power  
(S10420-1106)  
2048  
Num ber of pixels  
pixels  
µm  
-
Slit (H) × (V) *7  
70 × 800  
0.22  
70 × 800  
0.22  
C1100008822CCAA ((CCCCDD TTYYPPEE))  
10 × 1000  
0.11  
10 × 1000  
0.11  
Optical NA  
Connector for optical fiber  
Operating tem perature *8  
Storage tem perature  
SMA905D  
+5 to +40  
-20 to +70  
-
°C  
°C  
C10082MD (CMOS TYPE)  
*1:  
A conversion factor for converting the im age sensor pixel num ber into a  
wavelength is recorded in the m odule. A calculation factor for converting the  
A/D converted count into the input light intensity is not provided.  
10-15  
10-13  
10-11  
10-9  
10-7  
LIGHT POWER * (W)  
*2: Depends on the slit opening. Values were m easured with the slit listed in the  
table “G eneral ratings / Absolute m axim um ratings”.  
*3: Typical  
* Light power incident on mini-spectrometer through slit  
(λ=500 nm, integration time: 10 ms to 10000 ms)  
KACCB0146EA  
*4: λ =320 to 900 nm  
*5: M easured under constant light input conditions  
*6: W hen m onochrom atic light of the following wavelengths is input, spectral stray light is defined as the ratio of the count m easured at the input  
wavelength, to the count m easured in a region of the input wavelength 40 nm .  
C10082CA/C10082CAH: 500 nm , C10083CA/C10083CAH: 650 nm  
*7: Entrance slit aperture size  
*8: No condensation  
1

与C10083CAH相关器件

型号 品牌 描述 获取价格 数据表
C10083MD HAMAMATSU Mini-spectrometer TM series Integrating optical system, image sensor and circuit

获取价格

C100A ETC Optoelectronic

获取价格

C100AJ-00 HUASHAN NPN SILICON TRANSISTOR

获取价格

C100B ETC Optoelectronic

获取价格

C100C ETC Optoelectronic

获取价格

C100F103F AMPHENOL Low cost, solid state temperature sensor

获取价格