Embedded Power for
Business-Critical Continuity
Rev.10.16.08_121
BXB100 Series
1 of 3
BXB100 Series
Single output
Total Power:
66ꢀ-ꢀ100ꢀW
Input Voltage: 18ꢀ-ꢀ36ꢀV
36ꢀ-ꢀ75ꢀV
# of Outputs: Single
ElectricalꢀSpecifications
Input
Inputꢀvoltageꢀrange:
24ꢀVinꢀnominalꢀ
48ꢀVinꢀnominalꢀ
18ꢀ-ꢀ36ꢀVdc
36ꢀ-ꢀ75ꢀVdc
Special Features
•ꢀ Industryꢀstandardꢀfootprint
•ꢀ Highꢀpowerꢀdensityꢀ
(36.5 W/in3)
•ꢀ MTBFꢀ>1.4ꢀmillionꢀhoursꢀ
(Bellcore 332)
Inputꢀcurrent:
Noꢀloadꢀ
100ꢀmAꢀmax.
20ꢀmAꢀmax.
4ꢀAꢀmax.ꢀ@ꢀloꢀmax.
andꢀVinꢀ=ꢀ0ꢀtoꢀ75ꢀV
5ꢀmAꢀpk-pk
RemoteꢀOFFꢀ
48ꢀVꢀmodelsꢀ
ꢀ
Inputꢀcurrentꢀ(max.):
(Seeꢀnoteꢀ4)
Inputꢀreflectedꢀripple:
(Seeꢀnoteꢀ6)ꢀ
•ꢀ InputꢀvoltageꢀtoꢀETS300-132-2
•ꢀ Adjustableꢀoutputꢀvoltage
•ꢀ Noꢀminimumꢀloadꢀrequired
•ꢀ Separateꢀcaseꢀgroundꢀpin
•ꢀ Undervoltageꢀlockoutꢀ(UVLO)
•ꢀ UL,ꢀVDEꢀandꢀCSAꢀsafetyꢀ
approvals
ActiveꢀlowꢀremoteꢀON/OFF:
(See note 7)
Logicꢀcompatiblity:
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀOpenꢀcollectorꢀrefꢀtoꢀ-input
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ1.2ꢀVdcꢀmax.
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀOpenꢀcircuit
ON:
OFF:
Undervoltageꢀlockout:
24ꢀVin:ꢀpower-upꢀ
24ꢀVin:ꢀpower-downꢀ
48ꢀVin:ꢀpower-upꢀ
48ꢀVin:ꢀpower-downꢀ
17ꢀV
16ꢀV
34ꢀV
•ꢀꢀ2ꢀyearꢀwarranty
32.5ꢀV
Start-upꢀtime:
(seeꢀnoteꢀ8)
Powerꢀupꢀ
RemoteꢀON/OFFꢀ
20ꢀms
20ꢀms
Output
Voltageꢀadjustability:
ꢀ
ꢀ
60%ꢀtoꢀ110%
±1.0%
Setpointꢀaccuracy:
Lineꢀregulation:
Loadꢀregulation:
Minimumꢀload:
Overshoot:
Lowꢀlineꢀtoꢀhighꢀlineꢀ
Full load to min. load
ꢀ
±0.05%
±0.10%
0ꢀ%
Atꢀturnꢀonꢀandꢀturn-offꢀ
None
Undershoot:
ꢀ
None
Rippleꢀandꢀnoise:
5ꢀHzꢀ-ꢀ20ꢀMHzꢀ(seeꢀnoteꢀ1)
3.3ꢀVꢀandꢀ5ꢀVꢀ
75ꢀmVꢀpk-pk,
20ꢀmVꢀrms
100ꢀmVꢀpk-pk,
30ꢀmVꢀrms
Safety
ꢀ
VDE0805/EN60950/IEC950ꢀ
12Vꢀandꢀ15ꢀVꢀ
ꢀ
UL1950
CSAꢀC22.2ꢀNo.ꢀ950ꢀ