BRIGHT VIEW
ULTRA BRIGHTNESS LED LAMP
ELECTRONICS CO.,LTD
PACKAGE CONFIGURATION
BVU-3K0WI4
DESCRIPTION
Dice Material :
Light Color :
GaN Blue
White Color
Water Transparent
Lens Color :
Stand-Off P/N : BVU-3K0WI4 R
RADIATION PATTERN
0°
-30°
30°
-60°
60°
100
75 50 25
0
25 50 75
100
Tolerance ± 0.25 ㎜
Relative Luminous Intensity ( Iv % )
ABSOLUTE MAXIMUM RATINGS AT Ta = 25 ℃
PARAMETER
MAX.
UNIT
mW
mA
Power Dissipation (PD)
120
Continuous Forward Current (IF)
30
Peak Forward Current ( 1/10 Duty Cycle , 10ms Pulse Width ) (IFP)
Reverse Voltage (VR)
100
mA
5
V
Derating Linear From 25 ℃
mA/oC
0.4
Operating Temperature Range (Topr)
Storage Temperature Range (Tstg)
-30 ℃ to + 80 ℃
-40 ℃ to + 100 ℃
Lead Solder Temperature 1.6 mm Below Package 260 ℃ for 5 seconds (Tsld)
ELECTRICAL / OPTICAL CHARACTERISTICS AT Ta = 25 ℃
PARAMETER
TEST COND.
I F = 20 mA
V R = 5V
MIN.
TYP.
MAX.
4.0
SYMBOL
V F
UNIT
V
3.2
Forward Voltage
10
I R
Reverse Current
Viewing Angle
μA
Deg
mcd
I F = 20 mA
I F = 20 mA
25
2θ1/2
I V
2180
2800
Luminous Intensity
BIN GRADE LIMITS (IF=20 mA) LUMINOUS INTENSITY / mcd
Bin
P
Q
R
S
Tolerance ± 15%mcd
Min.
Max.
4650
6000
6000
7800
7800
10000
10000
13000
Please contact our sales department for more
information.
BIN GRADE LIMITS (IF=20 mA) CHROMATICITY COORDINATESL
x
y
x
y
x
y
x
y
0.260
0.240
0.275
0.260
0.290
0.280
0.305
0.305
0.260 0.275 0.275
0.280 0.300 0.260
0.275 0.290 0.290
0.300 0.320 0.280
0.290 0.305 0.305
0.320 0.345 0.305
0.305 0.320 0.320
0.345 0.370 0.330
x
y
x
y
x
y
x
y
0.320 0.320 0.335 0.335
0.330 0.370 0.390 0.350
0.335 0.335 0.350 0.350
0.350 0.390 0.410 0.370
0.350 0.350 0.365 0.365
0.370 0.410 0.430 0.390
0.365 0.365 0.380 0.380
0.390 0.430 0.450 0.410
WA1
WA2
WB1
WB2
WC1
WC2
WD1
WD2
*Bright View reserves the rights to alter specifications and remove availability of products at any time without notice.
*Dominant Wavelength, λd is according to CIE Chromaticity Diagram base on color of lamps.
*θ1/2 is the off-axis angle where the luminous intensity is one half the on-axis intensity.
*These products are sensitive to static electricity. Caution must be taken strictly to avoid static electricity.
2009/7/22 – C