BR150
Miniature 4PDT Dry Circuit to 2 Amp To
MIL-PRF-39016
Miniature
4PDT
Dry Circuit to 2 Amp
To MIL-PRF-39016
SPECIFICATIONS
ENVIRONMENTAL
GENERAL
Temperature Range...............................-65oC to +125oC
Vibration (Note 2)...............................0.4" DA 10 - 38 Hz,
30 G's 38 - 2,000 Hz
Contact Arrangement..........................4PDT (4 Form C)
Weight.............................................................0.3 oz max.
Designed to meet the requirements of MIL-PRF-39016/14
Shock (Operating) (Note 2) ........................75 G's 11 ms
PERFORMANCE
Contact Rating (Note 1)
ELECTRICAL CHARACTERISTICS
Resistive ..........................................2 Amp @ 28 VDC
0.5 Amp @ 115V 60 + 400 Hz
Duty Cycle......................................................C.. ontinuous
Insulation Resistance
(Case Ungrounded)
10,000 megohms @ 500V 25oC
Inductive........................................0.5 Amp @ 28 VDC
Lamp .............................................0.1 Amp @ 28 VDC
Low Level .............................10-50µA @ 10-50 mv DC
or peak AC (Note 4)
1,000 megohms @ 500V 125oC
Dielectric Strength:
Sea Level:
Contact to Case......................................750 VRMS
Contact to Coil ........................................750 VRMS
Coil to Case ............................................500 VRMS
Across Open Contacts ...........................500 VRMS
70,000 Feet
Life ...................................100,000 operations minimum
@ 1 amp load, 125oC
Pull In Power ...........................................2. 50 mw approx.
Operate/Release Time ....................4 ms max, excluding
bounce time at nominal coil voltage
Contact Bounce Time......................2 ms max @ 1 Amp
28 VDC contact load
All points..................................................350 VRMS
Contact Resistance
Before Life.........................0.050 Ohms max @ 1 Amp
and 6 VDC
After Life............................0.150 Ohms max @ 1 Amp
and 6 VDC
M39016/14 QUALIFIED to ER level M
Notes
1. For case grounded loads and other ratings, consult the
factory.
3. For other ratings consult the factory.
4. Relay contacts which have switched high level currents
are no longer suitable for switching low level loads.
2. For applications requiring other shock and vibration
levels, consult the factory.
www.microsemi.com
© 2015 Microsemi Corporation
April 2015 Rev. 3
1