BQ79656-Q1
SLUSEI2 – MAY 2021
BQ79656-Q1, BQ79654-Q1, BQ79652-Q1 Functional Safety-Compliant Automotive
16S/14S/12S Battery Monitor, Balancer and Integrated Hardware Protector with
Integrated Current Sense
1 Features
2 Applications
•
•
Qualified for automotive applications
AEC-Q100 Qualified with the following results:
– Device temperature grade 1: –40°C to +125°C
ambient operating temperature range
– Device HBM ESD classification level 2
– Device CDM ESD classification level C4B
Functional Safety-Compliant
•
•
•
Battery Management System (BMS) in hybrid and
electric powertrain systems
Energy storage battery packs with Battery
Management Systems
E-bikes, E-Scooters
3 Description
•
The BQ7965x-Q1 family of devices provides high-
accuracy cell voltage measurements for a minimum
of 6S to a maximum of 12S (BQ79652-Q1),
14S (BQ79654-Q1), or 16S (BQ79656-Q1) battery
modules in less than 200 µs while these devices also
support shunt-resistor current sense measurement.
The integrated front-end filters enable the system to
implement with simple, low voltage raring, differential
RC filters on the cell input channels. The integrated,
post-ADC, low-pass filters enable filtered, DC-like,
voltage measurements. This family of devices also
supports integrated current sensing capabilities with
option to synchronize with cell voltage measurements
for better state of charge (SOC) calculation. The
device supports autonomous internal cell balancing
with temperature monitoring to auto-pause and
resume balancing to avoid an overtemperature
condition.
– Developed for functional safety applications
– Documentation to aid ISO 26262 system design
– Systematic capability up to ASIL D
– Hardware capability up to ASIL D
+/- 1.5mV ADC accuracy
•
•
Pin-package and software compatible device
family:
– Stackable monitor 16S (BQ79616-Q1,
BQ79656-Q1), 14S (BQ79614-Q1, BQ79654-
Q1), and 12S (BQ79612-Q1, BQ79652-Q1)
– Standalone monitor 48 V system (BQ75614-
Q1)
Supports current-sense measurement
Built-in redundancy path for voltage and
temperature and current diagnostics
Highly accurate cell voltage measurements within
128 µs for all cell channels
•
•
•
•
Integrated post-ADC configurable digital low-pass
filters
Device Information
PART NUMBER (1)
BQ79652-Q1(2)
BQ79654-Q1(2)
BQ79656-Q1
PACKAGE
BODY SIZE (NOM)
•
•
Supports bus bar connection and measurement
Built-in host-controlled hardware reset to emulate
POR-like device reset
Supports internal cell balancing
– Balancing current at 240 mA
HTQFP (64-pin)
10.00 mm × 10.00 mm
•
– Built-in balancing thermal management with
automatic pause and resume control
Isolated differential daisy chain communication
with optional ring architecture
Embedded fault signal and heartbeat through
communication line
(1) For all available packages, see the orderable addendum at
the end of the data sheet.
(2) Product Preview
•
•
FUSE
Relay
fuse/relay sense
GPIOx
•
•
5 V LDO output to power external digital isolator
UART/SPI host interface/communication bridge
device BQ79600-Q1
12 V
BQ7961x
OUT
VCC
IN
PMIC
Daisy chain
communication
ISO
GPIOx
•
Built-in SPI master
BQ7965x CVDD
UART
VCC1 VCC2
MCU
Current sense
Rs
Simplified System Diagram
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,
intellectual property matters and other important disclaimers. UNLESS OTHERWISE NOTED, this document contains PRODUCTION
DATA.