APPLICABLE STANDARD
Operating
Storage
Temperature Range
-55C to 85C (Note 1)
-10C TO 60C
Temperature Range
Voltage
30V AC/DC
RATING
Signal contact : 0.3A
Current
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
According to drawing.
X
X
X
X
Marking
ELECTRIC CHARACTERISTICS
Contact Resistance
20mV AC or less 1kHz,1m A .
Signal contact resistance: 100 mMAX.
X
-
Insulation Resistance
Voltage Proof
100V DC.
100 M MIN.
X
X
-
-
150V AC for 1 min.
No flashover or breakdown.
VSWR 1.3 Max.
Frequency 0
Frequency 3
Frequency 6
~
~
~
3 GHz
6 GHz
12 GHz
Voltage Standing Wave
Ratio
VSWR 1.4 Max.
X
-
VSWR 1.6 Max
MECHANICAL CHARACTERISTICS
① Signal contact resistance: 100 mMAX.
② No damage, crack or looseness of parts.
Mechanical Operation
10times insertions and extractions.
X
X
-
-
Frequency 10 to 55 to 10 Hz, approx 5min,
Single amplitude 0.75 mm,10cycles,
for 3 directions.
490 m/s2 duration of pulse 11 ms at 3 times
for 3 directions.
① No electrical discontinuity of 1 s.
② No damage, crack or Looseness of parts.
Vibration
Shock
① No electrical discontinuity of 1 s.
② No damage, crack or looseness of parts.
X
-
ENVIRONMENTAL CHARACTERISTICS
Temperature -55 → +85C
① Signal contact resistance: 100 mMAX.
② Insulation resistance: 100M MIN.
③ No damage, crack or looseness of parts.
Rapid Change of
Temperature
Time
Under 5 cycles.
30 → 30 min
X
-
(Relocation time to chamber : within 2-3 min)
① Signal contact resistance: 100 mMAX.
② Insulation resistance: 50M MIN.
③ No damage, crack or looseness of parts.
Damp Heat
(Steady state)
Exposed at 40 ± 2 C, 90 to 95 , 96 h.
X
X
-
-
Signal contact resistance: 100 mMAX.
Exposed in 25 PPM for 96h, 25C, 75%.
(Refer to IEC 60068-2-42 Test Kc)
Sulfur Dioxide
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARKS
Note1: Include the temperature rising by current
APPROVED
CHECKED
DESIGNED
DRAWN
WR.FUKUCHI
20191024
20191024
20191024
20191024
TS.MIYAZAKI
RH.KITAGAWA
RH.KITAGAWA
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-378955-53-00
BM46B-12DS-0.35V(53)
SPECIFICATION SHEET
0
△
1/1
HIROSE ELECTRIC CO., LTD.
CL673-7054-0-53
FORM HD0011-2-1