Coaxial
Low Pass Filter
BLP-15+
50Ω
DC to 15 MHz
Features
Maximum Ratings
Operating Temperature
-55°C to 100°C
-55°C to 100°C
0.5W max.
• rugged shielded case
CASE STYLE: FF55
Connectors Model
Storage Temperature
• other standard and custom PLP models available with
wide selection of fco
RF Power Input
Permanent damage may occur if any of these limits are exceeded.
BNC
BLP-15+
Applications
• test equipment
• lab use
• transmitters/receivers
• military/hi-rel applications
+RoHS Compliant
The +Suffix identifies RoHS Compliance. See our web site
for RoHS Compliance methodologies and qualifications
Low Pass Filter Electrical Specifications
PASSBAND
(MHz)
fco (MHz)
Nom.
STOPBAND
(MHz)
VSWR
(:1)
Passband
Typ.
Stopband
Typ.
Outline Drawing
(loss < 1 dB)
DC-15
(loss 3 dB)
17
(loss > 20 dB)
23-32
(loss > 40 dB)
32-200
1.7
18
typical frequency response
electrical schematic
40 dB
R F IN
R F OUT
20 dB
3 dB
1 dB
DC
0.9
1
1.35
1.75
3
inch
Outline Dimensions (
)
FR E QUE NC Y / Fco
mm
Typical Performance Data
B
D
wt
Return Loss
(dB)
Frequency
(MHz)
Frequency
(MHz)
Insertion Loss
Group Delay
(nsec)
.54
2.59 grams
(dB)
13.72 65.79
40.0
_
σ
x
1.00
3.00
5.00
7.00
9.00
0.21
0.26
0.30
0.33
0.38
0.47
0.58
0.81
0.04
0.04
0.04
0.05
0.05
0.07
0.07
0.06
0.37
0.63
0.57
0.53
0.50
0.48
0.48
0.47
0.50
0.60
0.70
0.86
1.02
1.48
6.04
4.69
4.39
4.80
3.87
4.95
3.64
5.21
24.91
20.32
20.46
25.27
24.09
20.00
19.00
16.36
7.61
2.63
2.04
1.72
1.51
1.36
1.25
1.15
0.99
0.86
0.76
0.67
0.60
0.55
0.22
0.12
0.09
0.08
0.07
0.07
0.06
0.06
1.00
1.10
1.30
1.40
1.60
1.80
2.00
2.30
2.50
2.90
3.20
3.60
4.00
4.60
5.10
5.80
6.50
48.07
47.91
48.21
47.67
48.07
47.68
48.30
48.44
48.37
48.63
48.63
48.80
48.88
49.48
49.49
50.43
50.77
51.87
53.05
54.47
56.61
60.33
66.08
80.27
100.53
81.42
43.84
28.31
15.72
10.37
11.00
13.00
15.00
17.00
19.00
19.80
20.60
21.40
22.20
23.00
23.80
25.40
27.10
28.70
30.40
32.00
33.60
54.40
75.20
96.00
116.80
137.60
158.40
179.20
200.00
2.32
8.82
12.25
15.66
18.93
22.02
24.94
27.72
32.87
37.90
42.24
46.55
50.45
54.18
77.82
77.17
81.80
80.95
80.75
83.26
79.58
80.96
7.30
8.20
9.30
10.40
11.70
13.10
15.00
17.00
18.80
21.10
23.00
26.60
30.00
RETURN LOSS
at RF level of 0 dBm
INSERTION LOSS
GROUP DELAY
40
at RF level of 0 dBm
at RF level of 0 dBm
100
80
60
40
20
0
150
120
90
60
30
0
32
24
16
8
0
1
10
100
1000
0
40
80
120
160
200
0
6
12
18
24
30
FREQUENCY(MHz)
FREQUENCY(MHz)
FREQUENCY (MHz)
Notes
A. Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document.
B. Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions.
C. The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled
to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp
REV. C
®
M151107
BLP-15+
150609
Mini-Circuits
www.minicircuits.com P.O. Box 350166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com