1/4" x 1-1/4" Fuses
MDL Series, Time Delay, Glass Tube
Description
RoHS
2002/95/EC
• Time delay, glass tube
• Optional axial leads available
• 1/4 x 1-1/4 (6.3mm x 32mm) physical size
• Glass tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
ELECTRICAL CHARACTERISTICS
Rated Current
Amp Rating
100%
Opening Time
None
1/16 - 30A
135%
200%
200%
200%
60 minutes max.
120 seconds max.
5 seconds min.
12 seconds min.
Dimensions (mm⁄in
Drawing Not to Scale
)
1/16 - 3A
3-2/10 - 8A
Agency Information
UL Listed Card: MDL 1/16 - 8A (Guide JDYX, File E19180)
•
• UL Recognized Card: MDL 9 - 30A (Guide JDYX2,
File E19180)
• CSA Certification Card: MDL 1/16 - 8A
(Class No. 1422-01)
• CSA Component Acceptance: MDL 9-30A
(Class No. 1422-30)
Environmental Data
• Shock: 1/100A and 8/10A – MIL-STD-202,
Method 213, Test Condition I; 1A thru 30A –
MIL-STD-202, Method 207, (HI Shock)
• Vibration: 1/100A and 8/10A – MIL-STD-202,
Method 201; 1/4A thru 30A – MIL-STD-202,
Method 204, Test Condition C (Except 5g, 500HZ)
Ordering
• Specify packaging, product, and option code
SPECIFICATIONS
Voltage
Rating
AC
AC Interrupting
Typical DC Cold
Resistance**
(ohms)
38.000
15.900
9.850
Typical
Typical
Voltage
Drop‡
2.79
1.95
1.52
2
Product Code
Rating*
125V
Melting I t†
250V
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
100A
100A
100A
100A
100A
100A
200A
200A
200A
200A
200A
200A
-
32V
-
AC
0.0046
0.0420
0.0422
0.116
0.314
0.447
0.412
0.982
1.656
4.343
11.498
86.2
22.7
62.3
49.6
63.1
67.5
19.3
32.0
37.4
MDL-1/16
MDL-1/10
MDL-1/8
MDL-3/16
MDL-2/10
MDL-1/4
MDL-3/10
MDL-3/8
MDL-1/2
MDL-3/4
MDL-1
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
32V
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
10000A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4.680
4.115
3.200
2.300
2.800
1.725
0.822
0.525
0.320
0.250
0.173
0.068
0.096
0.067
0.035
0.023
0.018
0.018
0.018
0.011
0.009
0.008
0.006
0.002
1.05
0.972
0.965
0.808
1.46
1.27
1.01
0.995
0.722
0.721
0.644
0.535
0.410
0.345
0.187
0.160
0.155
0.152
0.140
0.119
0.124
0.114
0.130
0.530
0.30
MDL-1-1/4
MDL-1-1/2
MDL-2
MDL-2-1/4
MDL-2-1/2
MDL-3
MDL-4
-
-
-
-
-
-
MDL-5
MDL-6
MDL-6-1/4
MDL-7
38.7
42.7
47.8
51.5
MDL-8
MDL-9
MDL-10
MDL-15
MDL-20
MDL-25
MDL-30
1000A
1000A
1000A
1000A
1000A
1000A
32V
32V
32V
32V
-
-
-
-
-
-
-
-
64.4
354.0
2914.0
15221.0
15581.0
0.001
0.001
32V
-
-
0.40
*
Interrupting Ratings (Interrupting ratings were measured at 70% - 80% power factor on AC)
** DC Cold Resistance (Measured at ≤10% of rated current)
†
‡
Typical Melting I2t (A2Sec) (I2t was measured at listed interrupting rating and rated voltage.)
Typical Voltage Drop (Voltage drop was measured at 25°C 3°C ambient temperature at rated current)
OC-88