Europe: +49 / 7731 8399 0
USA: +1 / 508 295 0771
Asia: +852 / 2955 1682
| Email: info@meder.com
Item No.:
| Email: salesusa@meder.com
| Email: salesasia@meder.com
8805171700
Item:
BE05-1E66-M
BE05-1E71-M
Coil Data at 20 °C
Conditions
Min
Typ
Max
Unit
Coil resistance S1
Coil resistance S2
Coil voltage
Rated power
Thermal resistance
765
765
850
850
5
29
56
935
935
Ohm
Ohm
VDC
mW
max. Relay temperature
operating temperature + self heating
K/W
=
Pull-In voltage
Drop-Out voltage
0,8
0,8
3,8
3,8
VDC
VDC
Contact data 66
Conditions
Min
Typ
Max
10
Unit
W
Any DC combination of V & A
Contact rating
not to exceed their individual max.'s
Switching voltage (<21 AT)
Switching voltage (>20 AT)
Switching current
Carry current
Contact resistance static
DC or Peak AC
DC or Peak AC
DC or Peak AC
DC or Peak AC
180
200
0,5
1,25
150
V
V
A
A
Measured with 40% overdrive
mOhm
Start Value
Insulation resistance
Breakdown voltage (<21 AT)
Operate time incl. bounce
Release time
RH <45 %, 100 VDC test voltage
according to IEC 255-5
measured with 40% overdrive
measured with no coil excitation
@ 10 kHz across open switch
10
200
GOhm
VDC
ms
ms
pF
0,5
0,1
Capacitance
0,2
Special Product Data
Conditions
Min
Typ
Max
Unit
Number of contacts
Contact - form
1
E - bistable NO
Dielectric Strength Coil/Contact
Insulation resistance Coil/Contact
Case color
according to IEC 255-5
RH <45%, 200 VDC measuring voltage
2
1
kV AC
TOhm
silver metallic
Metal
Housing material
Sealing compound
Connection pins
Reach / RoHS conformity
Polyurethan
cu-alloy tinned
yes
Modifications in the sense of technical progress are reserved
Designed at:
02.12.10
Designed by:
WKOVACS
Approval at:
Approval at:
16.02.11
Approval by:
Approval by:
CRUF
Last Change at:
Last Change by:
Version:
03