Data Sheet
BCR20CM-12LB
600V - 20A - Triac
R07DS1151EJ0200
Rev.2.00
Medium Power Use
Sep. 11, 2018
Features
•
•
•
IT (RMS) : 20 A
VDRM : 600 V
IFGTI, IRGTI, IRGT III: 30 mA(20mA) Note6
•
•
•
Tj: 150 °C
Non-insulated Type
Planar Passivation Type
Outline
RENESAS Package code: PRSS0004AG-A
(Package name: TO-220AB)
RENESAS Package code: PRSS0004AT-A
(Package name: TO-220ABA)
4
4
2, 4
1. T1 Terminal
2. T2 Terminal
3. Gate Terminal
4. T2 Terminal
3
1
1
2
3
1
2
3
Application
Motor control, Heater control, Power supply, Solid state relay, and other general purpose AC control applications.
Maximum Ratings
Parameter
Symbol
Voltage class
Unit
12
Repetitive peak off-state voltageNote1
Non-repetitive peak off-state voltageNote1
VDRM
VDSM
600
720
V
V
Parameter
Symbol
Ratings
Unit
Conditions
RMS on-state current
IT (RMS)
ITSM
I2t
20
A
Commercial frequency, sine full wave
360conduction, Tc = 126CNote3
60 Hz sinewave 1 full cycle, peak value,
non-repetitive
Surge on-state current
I2t for fusing
200
167
A
A2s
Value corresponding to 1 cycle of half wave
60 Hz, surge on-state current
Peak gate power dissipation
Average gate power dissipation
Peak gate voltage
PGM
PG (AV)
VGM
IGM
5
W
W
V
0.5
10
Peak gate current
2
A
Junction Temperature
Storage temperature
Tj
–40 to +150
–40 to +150
C
C
Tstg
R07DS1151EJ0200 Rev.2.00
Sep. 11, 2018
Page 1 of 8