R-GAGE Q130RA Sensor
Quick Start Guide
Radar-Based Sensors for Detection of Moving and Stationary Targets
This guide is designed to help you set up and install the Q130RA. For complete information on programming, performance, troubleshooting,
dimensions, and accessories, please refer to the Instruction Manual at www.bannerengineering.com. Search for p/n 208831 to view the Instruction
Manual. Use of this document assumes familiarity with pertinent industry standards and practices.
WARNING:
•
•
•
Do not use this device for personnel protection
Using this device for personnel protection could result in serious injury or death.
This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety
applications. A device failure or malfunction can cause either an energized (on) or de-energized (off) output condition.
Features and Indicators
3
1
4
2
LED
Color
Description
Power ON
1
2
Power
Green
Flashes in proportion to the
signal strength
Signal Strength Red
3
4
Output 1
Output 2
Amber
Amber
Output energized
Output energized
Figure 1. R-GAGE Features
Installation Instructions
Mount the Device
1. If a bracket is needed, mount the device onto the bracket.
2. Mount the device (or the device and the bracket) to the machine or equipment at the desired location. Do not tighten the mounting screws at
this time.
3. Check the device alignment.
This is done via the red Signal Strength LED or the Banner Radar Configuration Software.
4. Tighten the mounting screws to secure the device (or the device and the bracket) in the aligned position.
Wiring
Key:
1 = Brown
1
3
2
4
+
12-30V dc
2 = White
3 = Blue
4 = Black
–
Load 1
5 = Gray (Connect for use with remote input)
Load 2
5
Remote TEACH
shield (QD cordset)
Note: Banner recommends that the shield wire (quick-disconnect cordsets only) be connected to earth ground or dc common.
Shielded cordsets are recommended for all quick-disconnect models.
Original Document
208830 Rev. B
15 May 2019