品牌 Logo 应用领域
爱普科斯 - EPCOS /
页数 文件大小 规格书
8页 205K
描述
Three Phase EMI Filter, 250V, 50/60HzHz,

B84299D1160E001 数据手册

 浏览型号B84299D1160E001的Datasheet PDF文件第2页浏览型号B84299D1160E001的Datasheet PDF文件第3页浏览型号B84299D1160E001的Datasheet PDF文件第4页浏览型号B84299D1160E001的Datasheet PDF文件第5页浏览型号B84299D1160E001的Datasheet PDF文件第6页浏览型号B84299D1160E001的Datasheet PDF文件第7页 
Filters for Power Lines  
B84299-+1***-B1  
B84299-+1***-E1  
16 to 100 A, 100 dB from 150 kHz  
Filter für:Netzleitungen  
Two- and four-line filters  
16 to 100 A  
Single-stage  
Stopband attenuation up to 40 GHz  
Features  
General-purpose use through design with separate lines without intercoupling  
Use of single chokes  
Insertion loss to CISPR 17  
Design  
The electrical components are incorporated in an RF-tight case of stainless steel. The cables enter  
through glands. The RF-tight termination of the openings is produced by specially shaped lids.  
The conductors and equipment grounding conductor are connected by threaded bolts. The space  
around the fixing holes is left as bare metal (unpainted) to ensure good RF contact with metal sur-  
faces (chassis, ground).  
Protective measures (grounding)  
The high capacitances between the lines and ground require special protective measures. If there  
are no product-specific requirements, protection with a secondary ground wire (diameter min.  
10 mm2) in accordance with EN 50178 is necessary. For this purpose the filter case have connect-  
ing bolts at each end.  
Resistors are incorporated in the filter to discharge capacitors after turn-off.  
Installation  
Filters are supplied complete with all parts required for RF-tight installation (fixing screws, flanges,  
RF gaskets, cable glands) and installation instructions.  
No welding is needed on the shielding wall, so any subsequent installation is quite simple. And the  
uniform template of the attachment points allows straightforward replacement of a two-line filter by  
a four-line filter for example.  
Accessories and special versions  
RF-tight flexible connector fittings in widths of 25 and 40 mm are available for installation spaced  
away from the shielding wall.  
Filters with an EMP protection add-on for surge currents up to 100 kA per line are available on  
request.  
To match requirements, filters can be supplied with different kinds of EMC or shielding cable glands.  
Tests  
All filters are 100 % tested and the results are archived under a filters serial number. If required, a  
test report can be generated for the serial number.  
15 12/01  

与B84299D1160E001相关器件

型号 品牌 描述 获取价格 数据表
B84299-D1160-E1 EPCOS 250V, 50/60Hz, THREE PHASE EMI FILTER

获取价格

B84299D1320B001 EPCOS 250V, 50/60Hz, SINGLE PHASE EMI FILTER

获取价格

B84299-D1320-B1 EPCOS 250V, 50/60Hz, SINGLE PHASE EMI FILTER

获取价格

B84299D1320E001 EPCOS 250V, 50/60Hz, THREE PHASE EMI FILTER

获取价格

B84299-D1320-E1 EPCOS Three Phase EMI Filter, 250V, 50/60HzHz,

获取价格

B84299D1630B001 EPCOS Filters for Power Lines

获取价格