AC Relays
HARTMAN Aerospace Power Products
Features:
B-499 3PDT, Double Break, 35/200 Amps,
115 VAC, 400 Hz/28 VDC
• 3PDT Double Break Main Contacts
• Transient Suppression
• Mechanically Interlocked
• Economizing Coil
• 115 VAC, 400 Hz
• 28 VDC
• 35 to 200 Amps
• High Reliability
• Meets many requirements of MIL-R-6106
CONTACTOR CONFIGURATION
Dimensions for this product are expressed in inches.
Multiply values by 25.4 for millimeters.
Notes:
PRODUCT SPECIFICATIONS
Construction
Main Contacts:
Configuration
Current
Gasket Sealed, Vented
3PDT
Resistive A Contacts
200 Amps, 28 VDC
Resistive B Contacts
Resistive C Contacts
35 Amps, 28 VDC
35 Amps, 115 VAC, 400 Hz
Auxiliary Contacts:
Configuration
Voltage (Nominal)
Current (Resistive)
Coil Data:
2-SPDT
5 VDC
0.1 mA
Duty Cycle
Continuous (Economizing)
28 VDC
18 VDC Maximum
1 - 7 VDC
Voltage (Nominal)
Pick-Up Voltage
Drop-Out Voltage
Coil Current @ 28 VDC & +25°C
In-Rush
5.6 Amps Maximum
0.43 Amps Maximum
-55°C to +71°C
Hold
Operating Temperature
Life:
For factory-direct application assistance, contact the HARTMAN
product team at (419) 521-9500, Fax (419) 526-2749.
Electrical
Mechanical
Weight
50,000 Cycles
100,000 Cycles
3 Lbs. 10 Oz.
© 2004 by Tyco Electronics Corporation. All Rights Reserved.
HARTMAN and TYCO are trademarks.
Catalog (web doc only)
Revised 5-04
Dimensions are in inches and
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
www.tycoelectronics.com
C. America: 52-55-5-729-0425