AZ762P
20 A SPDT MINIATURE
POWER RELAY
FEATURES
• Latching relay
• Dielectric strength 4400 Vrms
• Epoxy sealed versions available
• 20 Amp switching
• High inrush current 500A / 2ms available
• UL, CUR le E44211
CONTACTS
Arrangement
SPDT (1 Form C)
SPST (1 Form A, 1 Form B)
GENERAL DATA
Ratings
Resistive load:
Life Expectancy
Mechanical
Electrical
Minimum operations
1 x 10 6
Max. switched power: 5000 VA
Max. switched current: 20 A
Max. switched voltage: 277 VAC
1 x 10 5 at 16 A 250 VAC Res.
Set Time (typical)
15 ms at nominal coil voltage
Rated Load
20 A at 250 VAC, Resistive, 20k cycles
16 A at 250 VAC, Resistive, 100k cycles
16 A at 250 VAC, Resistive, 50k cycles (Form C-NC)
6 A at 277 VAC, inductive, 100k cycles
1.5 HP at 250 VAC, Motor, 40k cycles
Reset Time (typical)
15 ms at nominal coil voltage
(with no coil suppression)
Min. Pulse Time
Max Pulse Time
75ms
1 min.
‘T’ High Inrush Version (Form A 5.0mm Only)
3300W at 277VAC, Electronic Ballast, 20k cycles
3000W at 220VAC, Tungsten, 6k cycles
Dielectric Strength
(at sea level for 1 min.)
4400 VAC coil to contact
1000 VAC between open contacts
1500W at 347VAC, Std. Ballast, 20k cycles
Surge Voltage
Coil to Contact
10,000V (at 1.2x50 µ s)
Material
Silver tin oxide, Tungsten/Silver tin oxide
< 50 milliohms initially (at 1A, 24 VDC)
Insulation
Resistance
1000 megohms min. at 20°C
500 VDC 50% RH
Resistance
Ambient Temperature
Operating
At nominal coil voltage
-40°C (-40°F) to 85°C (185°F)
0°C (32°F) to 40°C (104°F)
Storage
COIL
Vibration
0.062" DA at 10–55 Hz
10 g
Power
At Pickup Voltage
(typical)
1 Coil: 256 mW
2 Coils: 384 mW
Shock
Enclosure
P.B.T. polyester
Tinned copper alloy, P.C.
270°C (518°F)
5 seconds
Max. Continuous
Dissipation
1 Coil: 0.4 W
2 Coils: 0.6 W
Terminals
Temperature Rise
Max. Temperature
26°C (47°F) at nominal coil voltage
130°C (266°F)
Max. Solder Temp.
Max. Solder Time
Max. Solvent Temp.
Weight
80°C (176°F)
13 g
NOTES
1. All values at 23°C (73.4°F).
2. Relay may pull in with less than “Must Operate” value.
3. Speci cations subject to change without notice.
4. Check the relay set/reset state before energizing the relay in
application.
10/17/14