AS Series • Current Sense Inductors & Transformers
AS Series Current Sensors are designed as a low cost method of
controlling, monitoring or measuring AC currents. The sensors serve as
feedbackelementsbetweentheoutputandpulsecontrolcircuitryproviding
accurateregulationofswitchmodepowersupplies.
Features
• FullyencapsulatedforoptimalPCboardmounting
• Frequencyrangefrom20kHzto200kHz
• Primarycurrentratingto30Amps
• Primarytosecondaryisolatedto2500VAC
• MeetsVDEnorms
• Optimumperformanceoverdesignatedcurrentand
frequencyrange
• Competitivepricingduetohighvolumeproduction
• ManufacturedinanISO-9001:2000,TS-16949:2002
andISO-14001:2004certifiedfacility
• FullyRoHScompliant
Applications
Isolatedcurrentfeed-backsignalinSwitchModePowerSupplies • Motorcurrentload/overload • Lighting • SwitchControlsUltra-soundcurrent
• Highresolutionsonarcurrent • Isolatedbi-directionalcurrentsensorwithfullwavebridgerectifier
ElectricalSpecificationsat25°C
Sec. Term. (2
Resistance
)
(1)
(3)
Prim./Sec.
Ratio
L
DCR
sec
(Ohms Max.)
I
Volt µS (4)
Max.
sec
sec
Max.
Part Number
Schematic
(mH Min)
(Ohms Nom.)
50
AS-100
AS-101
AS-102
AS-103
AS-104
AS-105
AS-110
AS-111
AS-112
AS-113
AS-114
AS-115
1:50
1:100
6
0.6
1.1
300mA
150mA
75mA
50mA
30mA
40mA
300mA
150mA
75mA
50mA
30mA
40mA
175
350
25
100
1
3
1:200
100
250
700
1682
6
4.5
200
700
1:300
10.0
300
900
1:500
25.0
500
1500
3750
175
1:750
43.0
750
1:50CT
1:100CT
1:200CT
1:300CT
1:500CT
1:750CT
0.3 / 0.3
0.55 / 0.55
2.25 / 2.25
5.0 / 5.0
12.5 / 12.5
21.5 / 21.5
25 + 25
50 + 50
100 + 100
150 + 150
250 + 250
375 + 375
25
350
1
2
3
100
250
700
1682
700
900
1500
3750
Notes:
17.2
1) Lsec: Secondary inductance tested at 10kHz and 10mV for 1:50 through 1:500
Prim./Sec. ratios and 1kHz/10mV for Prim./Sec. ratio of 1:750
5.0
2) This nominal termination resistance value will yield approximately 1.0V
of output for each amp of current in a single turn sense line. The output
Voltage/Ampere of these devices can be increased or decreased linearly
over a restricted temperature range by adjusting the terminating resistance.
3) For Prim./Sec. Ratios of 1:50 through 1:500, the Isec value corresponds to a
maximum primary current of 15 Amp-turns rms while the Isec value for the ratio of
17.0
20.4
TALEMA
ASXXX
2
1
3
0.45x0.66
4 .0
6.35
(0.250)
12.7
1:750 corresponds to a max. primary current of 30 Amp-turns rms.
1
+
4) VµS = R t x Is x
2F
Rt (Ohms): Recommended Terminating Resistance
Is (A): Secondary Current
9.53
1
2
3
_
+
F (Hz): Frequency
_
5) Operating Temperature Range: -40°C to +120°C
6) Pin 2 is on Center-Tapped (CT) versions only
Primary Sense Current
THE TALEMA GROUP
•
World Wide Toroidal Specialists
(06-06) AS Series