ARX 4418 & 4417 Variable Amplitude Transceivers for
MACAIR A3818, A5690, A5232, A4905
& MIL-STD-1553
Features
CIRCUIT TECHNOLOGY
• ARX 4418 Transceiver meets MIL-STD-1553A&B,
www.aeroflex.com
Macair A3818, A4905, A5232 and A5690 specs
• ARX 4417 Transceiver meets MIL-STD-1553 specs
• Operates with 15 Volts to 12 Volts power supply
General Description
The
Aeroflex
Laboratories
transceiver models ARX 4418 and
ARX 4417 are new generation
monolithic transceivers which provide
full compliance with Macair and
MIL-STD-1553 data bus requirements
while providing variable amplitude
control.
The model ARX 4418 and model
ARX 4417 perform the front-end
analog function of inputting and
outputting data through a transformer
to a MIL-STD-1553 or Macair data
bus. The ARX 4418 can be
considered a "Universal" Transceiver
in that it is compatible with
MIL-STD-1553A, B, Macair A-3818,
A-4905, A-5232 and A-5690. The
ARX 4417 is compatible with
MIL-STD-1553A/B.
• Voltage source output for higher bus drive power
• Plug-in, flat package or low profile flat package
• Monolithic construction using linear ASICs
• Variable receiver threshold capability
• Variable TX Amplitude
• Processed and screened to Mil-STD-883 specs
• DESC SMD (Standard Military Drawing)
Design of these transceivers
reflects particular attention to active
filter performance.This results in low
bit and word error rate with superior
waveform purity and minimal zero
crossover distortion. The ARX4418
series active filter design has
additional high frequency roll-off to
provide the required Macair low
harmonic distortion waveform without
increasing the pulsedelay characteris-
tics significantly.
ARX 4418FP/4418 Transceivers
TX DATA OUT
TX DATA IN
OUTPUT
STAGE
DRIVER
SHAPING
TX DATA OUT
TX DATA IN
TX INHIBIT
V+
AMP CONTROL
Efficient transmitter electrical and
thermal design provides low internal
power dissipation and heat rise at
high and well as low duty cycles.
Variable amplitude is adjusted with
0–10 Vdc on the control pin. An
optional receiver input threshold
adjustment can be accomplished by
the use of the "Set Internal
Threshold" terminals.
EX THRESHOLD
DATA
DATA
DATA
RX DATA OUT
SET INTERNAL
THRESHOLD
COMP.
COMP.
EX THRESHOLD
DATA
+5 V
-12V or -15V
V-
RX DATA OUT
RX DATA IN
RX DATA IN
ACTIVE
FILTER
INPUT
AMP
+15V or +12V
STROBE
Block Diagram (without Transformer)
eroflex Circuit Technology – Data Bus Modules For The Future © SCD4418 REV B 10/18/99