Capable of 2A to 3A
high-frequency load
switching
HE 1 Form A
High Capacity (AQV251G, AQV252G)
FEATURES
TYPICAL APPLICATIONS
6.4
1. Greatly increased load current in a
compact DIP package
• Measuring instrument market
(Testers etc.)
8.8
.346
6.4
.252
3.6
.142
8.8
.346
.252
3.9
.154
Continuous load current: 3.5A
(AQV251G)
• Industrial machinery and equipment
• Power supply controls
• Security/Disaster prevention market
I/O sections of warning devices, security
systems, etc.
(Height includes standoff)
2. Greatly improved specifications
allow you to use this in place of
mercury and mechanical relays.
3. Low on-resistance (Typ. 35mΩ,
AQV251G)
mm inch
1
2
3
6
5
4
RoHS compliant
TYPES
Part No.
Output rating*
Packing quantity
Through hole
Surface-mount terminal
terminal
Package
Tape and reel packing style
Picked from the Picked from the
Load voltage
Load current
Tube packing style
Tube
Tape and reel
1,000 pcs.
1/2/3-pin side
4/5/6-pin side
1 tube contains:
50 pcs.
30 V
60 V
3.5 A
2.5 A
DIP6-pin
DIP6-pin
AQV251G
AQV252G
AQV251GA
AQV252GA
AQV251GAX
AQV251GAZ
AC/DC
dual use
1 batch contains:
500 pcs.
AQV252GAX
AQV252GAZ
*Indicate the peak AC and DC values.
Note: The surface mount terminal indicator “A” and the packing style indicator “X” or “Z” are not marked on the device.
RATING
1. Absolute maximum ratings (Ambient temperature: 25°C 77°F)
Type of
connection
Item
Symbol
AQV251G(A)
AQV252G(A)
Remarks
LED forward current
LED reverse voltage
Peak forward current
Power dissipation
IF
50 mA
5 V
VR
IFP
Pin
VL
Input
1 A
f = 100 Hz, Duty factor = 0.1%
75 mW
Load voltage (peak AC)
30 V
3.5 A
4.0 A
6.0 A
60 V
2.5 A
3.5 A
5.0 A
A
B
C
A connection: Peak AC, DC
B, C connection: DC
Continuous load current
IL
Output
Peak load current
Power dissipation
Ipeak
Pout
PT
6.0 A
100ms (1 shot), VL = DC
600 mW
650 mW
Total power dissipation
I/O isolation voltage
Viso
Topr
Tstg
1,500 Vrms
Operating
Storage
–40 to +85°C –40 to +185°F
–40 to +100°C –40 to +212°F
(Non-icing at low temperatures)
Ambient temperature
ASCTB144E 201703-T
–1–