25W Single Output Switching Power Supply
APV-25 series
■ Features :
ꢀConstant voltage mode power supply
ꢀUniversal AC input / Full range
ꢀWithstand 300VAC Surge input for 5 seconds
ꢀProtections: Short circuit / Over load / Over voltage
ꢀFully isolated plastic case
ꢀCooling by free air convection
ꢀSmall and compact size
ꢀIP42 design
ꢀClass 2 power unit
ꢀPass LPS
ꢀ100% full load burn-in test
ꢀLow cost, high reliability
ꢀSuitable for LED lighting and moving sign applications
ꢀ2 years warranty
LPS
IP42
SPECIFICATION
APV-25-12
APV-25-15
APV-25-24
APV-25-36
MODEL
APV-25-5
12V
15V
24V
36V
DC VOLTAGE
5V
2.1A
1.68A
1.05A
0.7A
RATED CURRENT
CURRENT RANGE
RATED POWER
3.5A
0 ~ 2.1A
25.2W
150mVp-p
0 ~ 1.68A
25.2W
0 ~ 1.05A
25.2W
0 ~ 0.7A
25.2W
150mVp-p
0 ~ 3.5A
17.5W
150mVp-p
RIPPLE & NOISE (max.) Note.2 120mVp-p
VOLTAGE TOLERANCE Note.3 5.0%
150mVp-p
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
1.0%
2.0%
Note.6 1500ms, 30ms / 230VAC
1500ms,30ms / 115VAC at full load
20ms/230VAC
Note.4 90 ~ 264VAC
47 ~ 63Hz
12ms/115VAC at full load
127 ~ 370VDC
82%
83%
83%
84%
75.5%
INPUT
0.4A/230VAC 0.8A/115VAC
COLD START 45A(twidth=310μs measured at 50% Ipeak) at 230VAC
INRUSH CURRENT(Typ.)
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
9 units (circuit breaker of type B) / 15 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
OVER LOAD
0.25mA / 240VAC
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
ENVIRONMENT
13.8 ~ 16.2V
17.25 ~ 21V
27 ~ 32.4V
41.4 ~ 48.6V
5.75 ~ 6.95V
OVER VOLTAGE
WORKING TEMP.
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ 70℃(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80℃, 10 ~ 95% RH
0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL8750 , CSA-C22.2 No. 250.0-13, IP42 approved; design refer to EN60950-1
I/P-O/P:3KVAC
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
SAFETY &
EMC
I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022,EN61000-3-2 Class A,EN61000-3-3
Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A
692.8K hrs min. MIL-HDBK-217F (25℃)
EMC IMMUNITY
MTBF
84*57*29.5mm (L*W*H)
OTHERS
NOTE
DIMENSION
0.13Kg; 72pcs / 10.4Kg / 0.92CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7.The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
File Name:APV-25-SPEC 2016-11-10