VDE
Pending
THE SLIM POWER RELAY
FEATURES
PE-RELAYS
5
• Slim size
Insulation complying to following standards:
EN 60255 General specification for electrical relays
EN 60335 For use in house-hold appliances
EN 60730 For use in temperature sensing appliances
EN 60950 For use in electrical business equipment
EN 60065 For use in entertainment electronics
(radio, HiFi-sets)
.197
28
1.102
28 mm (L)×5 mm (W)×15 mm (H)
1.102 inch (L)×.197 inch (W)×.591 inch
(H)
15
.591
permits high density mounting
• Wide switching capacity:
100 mA/12 V DC-6A/250 V AC
EN 50178 For use in industrial range
• High sensitivity: 170mW
• High breakdown (4,000 V) and surge
(6,000 V) voltage between contacts
and coil
• Clearance/creepage distance: 8/8 mm
• 1 Form A/1 Form C contact.
SPECIFICATIONS
Contacts
Characteristics
Arrangement
1 Form A, 1 Form C
Initial insulation resistance*1
Min. 1,000 MΩ at 500 V DC
Au-plated
silver alloy
Betweenopen
contacts
Contact material
Silver alloy
1,000 Vrms
Initial breakdown
voltage*2
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Between con-
tacts and coil
100 mΩ
30 mΩ
4,000 Vrms
Nominal switching capacity
6 A 250 V AC
Surge voltage between contacts and
coil*3
Operate time*4 (at nominal voltage)
Release time (without diode)*4
(at nominal voltage)
Min. 6,000 V (Initial)
Max. 8 ms (approx. 5 ms)
Max. 4 ms (approx. 2.5 ms)
Maximum switching power
Maximum switching voltage
Max. switching current
1,500 VA
400 V AC/300 V DC
6 A (AC)
Rating (resis-
tive)
Mechanical (at 180 cpm)
5×106
N.O.: 5×104
N.C.: 3×104
Expected life
(min.opera-
tions)
Max. 30°C with nominal coil
voltage across
coil and at nominal switching
capacity
1 Form C: Min. 49 m/s2{5 G}
1 Form A: Min. 98 m/s2{10 G}
Electrical (at 6 cpm)
(at rated load)
Temperature rise
Coil (at 25°C 77°F, 50% R.H.)
Nominal operating power
Remarks
Functional*5
170 mW (4.5 to 24 V DC)
217 mW (48 V DC)
Shock resistance
Destructive*6
Min. 980 m/s2 {100 G}
10 to 55 Hz
at double amplitude of 1.0 mm/6 G
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Intial breakdown voltage" section
*2 Detection current: 10mA
Functional*7
Vibration resistance
10 to 55 Hz
at double amplitude of 1.5 mm/9 G
*3 Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*4 Excluding contact bounce time
Destructive
*5 Half-wave pulse of sine wave: 50ms; detection time: 10µs
*6 Half-wave pulse of sine wave: 11ms
Conditions for operation,
transport and storage*8
(Not freezing and condens-
ing at low temperature)
Ambient
temp.
–40°C to +85°C
–40°F to +185°F
*7 Detection time: 10µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Humidity
5 to 85%R.H.
Unit weight
Approx. 4 g .14 oz
TYPICAL APPLICATIONS ORDERING INFORMATION
• Interface relays for programmable con-
trollers
Ex. APE
0
• Output relays for measuring equipment,
timers, counters and temperature con-
trollers
• Industrial equipment, office equipment
• House-hold appliances for Europe
Contact arrangement
Contact type
0: Single contact
Contact material
Coil voltage (DC)
1: 1 Form A
3: 1 Form C
0: Silver alloy
1: Au-plated silver alloy
4H: 4.5 V 18: 18 V
06: 6 V
24: 24 V
12: 12 V 48: 48 V
(Notes) 1. Standard packing: Tube: 20 pcs.; Case: 1,000 pcs.
2. 5 V, 60 V type is also available.
3. 1 Form B is also available.
211