Motion-Detecting Sensor (AMP)
MOTION-DETECTING
SENSOR
(PASSIVE INFRARED TYPE)
AMP Series
Highly sensitive type
• Varied operation in accordance with
the surrouding brightness
24×24 mm .945×.945 inch
• High detection ability
If used together with a brightness
sensor (CdS), you can make the sensor
operate only during bright hours or dark
hours.
• Output time can easily be changed
By simply changing the resistor
attached to the outside of the sensor,
the output time can be changed from
approximately 10 seconds to 6 minutes.
This sensor is a stable, sensitive sensor
that detects 2°C 3.6°F temperature
changes regardless of the location or
speed of the subject. In other words,
this sensor ensures detection whether a
person is at the edge of the detection
area or in the middle, regardless of how
fast they are moving.
FEATURES
• Detects even slight motion of a per-
son (e.g. a 20 cm 7.87 inch move-
ment of the hand)
With our unique motion detector—high-
ly sensitive type, even slight motions
made by people will be detected easily.
• Compact lens
We have decreased the exposed por-
tion of the lens, and at the same time
maintained a detection ability that is as
good or better than other motion sen-
sors on the market.
• Low current consumption
The standard model consumes 260 µA
(during stand-by), while the low con-
sumption current type consumes 30 µA
(during stand-by). This makes battery
operation possible.
• Wide operation voltage range (2.6 to
5.5 V DC)
The usable range extends from a
standard 5 V DC for microcomputers to
3 V DC and 4.5 V DC for battery opera-
tion.
TYPICAL APPLICATIONS
• Lighting and ventilation control of con-
ference rooms
• Control of illumination and exhaust fans
in toilets
• Lighting control of halls
• Nighttime lighting control of vending
machines
Lens dimensions:
Standard sensitive type
• Lightning control around cash dispens-
ing machines (ATMs)
16×20 mm .630×.787 inch
ORDERING INFORMATION
Ex. AMP
0
9
Detection performance
Current consumption
Lead wire
Operating voltage
9: 2.6 to 5.5 V DC
1: Standard sensitive type: 0.3 to 2.0 m/s 0: Standard type
0: No lead wire type
2: Highly sensitive type: 0.3 to 1.0 m/s
1: Low current consumption type
TYPES
Packing quantity
Detection
Current consumption
performance
Rated operating voltage
2.6 to 5.5 V DC
Part No.
Inner
Outer
Standard type
AMP1009
AMP1109
AMP2009
AMP2109
Standard
sensitive type
Low current consumption type
Standard type
20 pcs.
200 pcs.
Highly
sensitive type
Low current consumption type
PERFORMANCE
1. Detection performance (Measuring conditions: ambient temp.: 25°C 77°F; operating voltage: 5V DC)
Items
Rated detection distance
Horizontal
Detection
Vertical
range
Standard sensitive type
Highly sensitive type
Conditions of objects to be detected
5 m min.
95°
2 m min.
73°
1. To have more than 2°C 36°F of temperature
1. difference from background
2. Movement speed
• Standard sensitive type: 0.3 to 2.0 m/s
• Highly sensitive type: 0.3 to 1.0 m/s
3. Detection object = human body
55°
73°
Detection zone
34 zones
64 zones
2. Absolute maximum rating (Measuring condition: ambient temp.: 25°C 77°F)
Items
Specified value
7 V
Remarks
Power supply voltage
Voltage
Current
30 V
Output
(Open collector)
50 mA
Usable ambient temperature
Storage temperature
–20 to +55°C –4 to +131°F
–30 to +80°C –22 to +176°F
No freezing and condensing at low temperature.
10