Click on Series name for product info on aimtec.com
Series AMEPR15D-AZ
up to 1A | AC-DC LED Driver
FEATURES:
AC-DC Constant Current LED Driver
Input range 90-264VAC/47-440Hz
High Efficiency up to 82%
Operating temperature -20 to 80°C
Total Harmonic Distortion < 20%
5 Year Limited Warranty
Leading or Trailing Edge Triac
IP20 or IP67 Case
Active PFC with TRIAC Dimmable
SCP, Over Load Protection
②
Models
Single Output
No Load
Output
Voltage
(V max.)
Max
Output
Voltage
Range
(V)
Efficiency
Output
Power
Output
Current (A)
Input Voltage
(VAC/Hz)
(%)
Model
115
230
①
VAC
VAC
(W)
②
②
②
②
AMEPR15D-5030AZ+Suffix
AMEPR15D-4835AZ+Suffix
AMEPR15D-3650AZ+Suffix
AMEPR15D-2470AZ+Suffix
15
15.8
18
36-50
62
62
52
34
23
0.3
0.35
0.5
0.7
1
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
82
82
81
81
80
82
82
82
82
79
30-48
24-36
16.8
15
12-24
8-15
②
AMEPR15D-15100AZ+Suffix
①
Exceeding the maximum output power will permanently damage the converter.
②
Model Nomenclature for Ordering:
Add Suffix “-UD”
Universal AC input 90-264VAC, (no TRIAC dimming option), IP20
Universal AC input 90-264VAC, (no TRIAC dimming option), IP67
AC input 90-135VAC, IP20, 115VAC typical value
AC input 90-135VAC, IP67, 115VAC typical value
AC input 180-264VAC, IP20, 230VAC typical value
Add Suffix “-UW”
Add Suffix “-110D”
Add Suffix “-110W”
Add Suffix “-220D”
Add Suffix “-220W”
AC input 180-264VAC, IP67, 230VAC typical value
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-
sale
AMEPR15D-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Inrush current <2ms (cold start)
Leakage current
Conditions
115VAC
230VAC
Typical
Maximum
Units
A
15
25
25
mA
mA
115VAC
230VAC
115VAC
400
250
0.9
AC current
Power Factor
230VAC
0.9
Recommend Slow
Blown Type
External fuse
Start up time
1
A
200
ms
www.aimtec.com
F 052.1e R3.R
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only