O
Series AMEOF1-JZ
1 Watt | AC-DC Converter
Picture Coming Soon
FEATURES:
• Input: 85-264VAC, 47-440Hz or 70-400VDC
• Operating temperature -40°C to +85°C
• Low power consumption ≤ 0.5W
•
•
•
•
I/O Isolation 3000VAC
Ultra slim open frame SIP
Over current protection
Class II power supply
• Continuous short circuit protection
Models
Single output
Full power
temperature
range
Maximum
Input
Voltage
(VDC)
Output
Voltage
(V)
Output
Current max
(mA)
Input Voltage
capacitive
load
(µF)
Efficiency
(%)
Model
(VAC/Hz)
(ºC)
AMEOF1-5SJZ
AMEOF1-9SJZ
AMEOF1-12SJZ
AMEOF1-15SJZ
AMEOF1-24SJZ
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
85-264/47-440
70-400
70-400
70-400
70-400
70-400
-20 to +55
-20 to +55
-20 to +55
-20 to +55
-20 to +55
5
9
12
15
24
200
111
83
67
42
220
100
100
100
66
67
70
69
68
100
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Conditions
115VAC
230VAC
115VAC
230VAC
Typical
Maximum
Units
mA
mA
A
A
A
120
60
Current
9
15
1
Inrush current <2ms
External fuse
Input dissipation
Input filter
Recommended slow blow type
No Load
0.5
W
Recommended external π (Pi) filter
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Full load, 5V output
Full load, others
Full load
5% - 100% load
20MHz Bandwidth
115VAC
±8
±5
Voltage accuracy
%
Line regulation
Load regulation
Ripple & Noise
±1.5
±2.5
%
%
mV p-p
ms
ms
% of Max
120
40
180
5
Hold-up time (min)
230VAC
Minimum load current
Isolation Specifications
Parameters
Tested I/O voltage
Conditions
Typical
Rated
3000
Units
VAC
MΩ
60 sec
Isolation Resistance
>1000
General Specifications
Parameters
Switching frequency
Over current protection
Short circuit protection
Short circuit restart
Conditions
Typical
60
≥110
Continuous
Auto-recovery
-40 to +85
Maximum
Units
KHz
% of I out
Auto-recovery
Operating temperature
Storage temperature
See derating curve
°C
°C
-40 to +105
www.aimtec.com
F 052e R0
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only