Series AMEOC40-MAZ
40 Watt | AC/DC Converter
FEATURES:
• 4000VAC I/O isolation
•
•
•
•
Energy star compliant
RoHS compliant
Low ripple and noise
CE, cULus, CB approvals
• Operating temperature: -40°C to +85°C
• Over load, Over voltage, Short circuit protection
• Universal Input: 90-260VAC, 47-440Hz, or 120-370VDC
Models
Single output
CB
Output Current
Input Voltage
(VAC/Hz)
Input Voltage
Output Voltage
(V)
Efficiency
(%)
Model
max
(A)
8
(VDC)
AMEOC40-3.3SMAZ
AMEOC40-5SMAZ
AMEOC40-12SMAZ
AMEOC40-15SMAZ
AMEOC40-24SMAZ
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
90-264/47-440
120-370
120-370
120-370
120-370
120-370
3.3
5
12
15
24
78
82
84
83
82
8
3.33
2.66
1.66
Models
Dual output
Output Current
Input Voltage
Input Voltage
(VDC)
Output Voltage
(V)
Efficiency
(%)
Model
max
(A)
(VAC/Hz)
AMEOC40-5DMAZ
AMEOC40-12DMAZ
AMEOC40-15DMAZ
AMEOC40-24DMAZ
90-264/47-440
90-264/47-440
90-264/47-440
90-260/47-440
120-370
120-370
120-370
120-370
±5
±12
±15
±24
±4
80
85
82
77
±1.66
±1.33
±0.835
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Conditions
115 VAC
230 VAC
115 VAC
230 VAC
Typical
Maximum
1000
530
Units
Current
mA
25
50
Inrush current <2ms
A
Leakage current
External fuse
µA
A
150
Recommended slow blow type
No load; 115VAC
3.15
<0.5
<0.8
117
Input dissipation
Start-up time
W
No load; 264VAC
ms
Output Specifications
Parameters
Voltage accuracy
Line regulation
Conditions
Typical
±2
±0.5
Maximum
Units
%
%
(LL-HL)
0-100% load single
0-100% load dual
±1
±2
±5
Load regulation
%
Cross regulation
25% load - 1st out, 100% load – 2nd out
Depending of the model
25% load Step
%
µF
% of Vout
mV p-p
ms
Maximum Capacitive load
Transient response deviation
Ripple & Noise*
Hold-up time (min)
Minimum Load Current
470-23 000
±2
50
29
0
20MHz bandwidth
115VAC
% of Max
*Ripple & Noise measured with 0.1μF M/C and 1μF E/C
www.aimtec.com
F 052e R7.F
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only