AMEO125 Series
125 Watt (Open Frame) AC/DC Converter
Picture
Available
Soon
OPEN FRAME SWITCHING POWER SUPPLY
•
•
REGULATED OUTPUT
125W WITH 18CFM FAN
EFFICIENCY UP TO 75%
PFC FUNCTION
•
•
•
•
UNIVERSAL INPUT RANGE 90…264 VAC,
47…63HZ OR 120…370VDC
ULTRA COMPACT SIZE
•
•
3000 VAC INPUT-OUTPUT ISOLATION
ELECTRICAL SPECIFICATIONS
All specifications valid at nominal Input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No. (Single Output)
Max. Output Wattage (Convection)
Max. Output Wattage (18CFM Fan)
AMEO125-3.3S AMEO125-5S AMEO125-12S AMEO125-15S AMEO125-24S AMEO125-48S
66W
100W
125W
100W
125W
100W
125W
100W
125W
100W
125W
82.5W
Voltage
90-260 VAC or 120-370 VDC
47-63 Hz
Frequency (Hz)
Input
Current (Full Load)
Inrush Current (<2ms)
Leakage Current
3A Max. (115VAC) / 1.5A Max. (230VAC)
30A Max. (115VAC) / 60A Max. (230VAC)
3.5mA Max.
Power Factor
PF>0.97 (115VAC) / PF>0.93 (230 VAC) at Full Load
Voltage (VDC)
3.3V
5V
12V
15V
24V
48V
Voltage Accuracy
±2%
Max. Current (Convection)
Max. Current (18CFM Fan)
Line Regulation (LL-HL) (typ.)
Load Regulation (5-100%) (typ.)
Minimum Load
20A
25A
20A
25A
8.33A
10.4A
6.66A
8.33A
±1%
±1%
0%
4.16A
5.2A
2.08A
2.6A
Output
Maximum Capacitive Load
Ripple & Noise
Efficiency
Hold-up Time
Switching Frequency
Over Power Protection
Over Voltage Protection
Short Circuit Protection
Input-Output (VAC)
Input-FG (VAC)
Output-FG (VAC)
Operating Temperature (Conv)
Operating Temperature (Fan)
470-23,000µF Depending on model.
1% Max.
100mV Max.
68% 70%
75%
18ms Min.
67kHz
75%
75%
75%
Auto Recovery
Zener Diode Clamp
Auto Recovery
3000V
Protection
Isolation
1500V
500V
-25°C - +40°C (without derating)
-25°C - +50°C (without derating)
-40°C - +85°C
Environment Storage Temperature
Temperature Coefficient
Humidity
0.02% / °C (0-50°C)
95% RH
MTBF
> 100,000 hrs @ 25°C (MIL-HDBK-217F)
Physical
Dimensions (LxWxH)
Weight
5.00x3.00x1.40 Inches (127.0x76.2x35.5mm) Tolerance ±0.5mm
365g
Free Air Convection / 18CFM Forced Air
EN55022 Class B
Cooling Method
EMI (Conducted & Radiated Emission)
EMC
EMS (Noise Immunity)
EN55024
Specifications are subject to change without notification.
Continued on next page
VISIT US AT WWW.AIMTEC.CA