Click on Series name for product info on aimtec.com
Series AME20-JZ
20 Watt | AC-DC / DC-DC Converter
FEATURES:
I/O Isolation 3000VAC
Operating Temp: -40°C to +70°C
Over current Protection
Low Ripple and Noise
Over Voltage Protection
Up to 85% efficiency
Short Circuit Protection
Input: 85-305VAC, 47-63Hz, or 100-430VDC
Models
Single output
Efficiency
Max
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Output
Voltage
(V)
Output
Maximum
(%)
Output
wattage
(W)
Model
Current max capacitive load
230
(A)
(µF)
VAC
AME20-3.3SJZ
AME20-5SJZ
AME20-9SJZ
AME20-12SJZ
AME20-15SJZ
AME20-24SJZ
85-305/47-63
85-305/47-63
85-305/47-63
85-305/47-63
85-305/47-63
85-305/47-63
100-430
100-430
100-430
100-430
100-430
100-430
11.5
17.5
18.9
19.2
19.5
20
3.3
5
9
12
15
24
3.5
3.5
2.1
1.6
1.3
0.85
48000
12240
5600
5400
2400
1840
75
78
79
83
84
85
Input Specifications
Parameters
Conditions
Typical
Maximum
Units
mA
mA
A
A
mA
A
115 VAC
230 VAC
115 VAC
230 VAC
600
340
Current (full load)
15
30
Inrush current <2ms (cold start)
Leakage current
External fuse
0.25
Recommended slow blow type
3.15
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Ripple & Noise
Conditions
Typical
±2
±0.5
±1
Maximum
Units
%
%
%
mV p-p
ms
(LL-HL)
10-100% load
100
±10
115 VAC
230 VAC
15
80
Hold-up time
ms
% of Vout
Voltage adjustment range
Isolation Specifications
Parameters
Conditions
Input to Output, 60 sec
Input to Ground
Typical
Rated
3000
2000
Units
VAC
MΩ
Tested I/O voltage
Isolation resistance
>1000
General Specifications
Parameters
Switching frequency
Conditions
Typical
65
Maximum
Units
KHz
Over current protection
Over voltage protection
Short circuit protection
Operating temperature
Maximum case temperature
Storage temperature
≥110
Zener Diode Clamp
Auto recovery
% of Iout
See derating curve
-40 to +70
°C
°C
°C
100
-40 to +105
±0.02
Temperature coefficient
% / °C
www.aimtec.com
F 052e R8.A
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only