VER : PA_2
update : 2012.05.10
LED Power
ALF80 SERIES
80 Watts
KEY FEATURES
IP65/67 Design for Indoor or LED Outdoor Installations
Universal Input: 90-305 VAC or 120-430 VDC
Three in one dimming function
(1~10VDC & PWM Signal or resistance)
Bulit-in Active PFC Function
Free Air Convection
High Reliability
With Constant Current & Constant Voltage
Output Voltage and Constant Current Level can Be
Adjusted Through Internal Potential Meter
LED Power Application
3-Years Product Warranty
ELECTRICAL SPECIFICATIONS
Model No.
ALF80-12S
80W
ALF80-15S
ALF80-24S
ALF80-48S
ALF80-54S
Max Output Wattage (W)
Voltage
90-305 VAC or 120-430 VDC
47-63 Hz
Frequency (Hz)
Current (Full load)
Input
0.85 A max. (115 VAC) / 0.425 A max. (230 VAC) / 0.4 A max. (277 VAC)
40 A max. (115 VAC) / 70 A max. (230 VAC)
<0.75 mA max.
Inrush Current (<2ms)
Leakage Current
Power Factor
PF>0.97 (115 VAC) / PF>0.9 (230 VAC) at Full Load
Voltage (V.DC.)
12V
15V
24V
48V
54V
6 ~ 12V
±2%
Constant Current Range (V.DC.)
Voltage Accuracy
7.5 ~ 15V
12 ~ 24V
24 ~ 48V
27 ~ 54V
Current (Convection) (mA) max
Current ADJ Range (mA)
6666
5333
3400
1700
1500
3333 ~ 6666
2667 ~ 5333
1700 ~ 3400
850 ~ 1700
750 ~ 1500
Voltage ADJ Range (V.DC.)
(for IP65 Design)
10.8 ~ 13.5V
13.5 ~ 17V
22 ~ 27V
43 ~ 53V
49 ~ 58V
Line Regulation
±1%
±1%
Output
Load Regulation
Minimum Load
Maximum Capacitive Load
Ripple & Noise (max.)
Efficiency (typ.)
150mVp-p
87%
150mVp-p
88%
150mVp-p
89%
200mVp-p
90%
200mVp-p
90%
Hold-up Time
25 ms min.
Switching Frequency
Over Power Protection
Over Voltage Protection
Overt Temperature Protection
Short Circuit Protection
Input-Output (V.AC)
Auto recovery
Auto recovery
Auto recovery
Auto recovery
3750V
Protection
Isolation
Input-FG
(V.AC)
1880V
Output-FG .(V.AC)
Operating Temperature
Storage Temperature
Temperature Coefficient
Humidity
500V
-40°C…+70°C (with derating)
-40°C…+85°C
±0.02%/°C ( 0~50°C )
95% RH
Environment
MTBF
>100,000 h @ 25°C (MIL-HDBK-217F)
Vibration
10~500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes.
1. All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.