LE
VDE
16A Power Relay For
Micro wave oven
LE RELAYS
4. Low operating power
FEATURES
12.4
.488
• Nominal operating power: 400mW/
200mW (High sensitive type)
5. A wide variety of types
• Product line consists of 4 types with dif-
ferent shapes and pins
6. Conforms to the various safety
standards:
• UL/CSA, TÜV, VDE approved and
SEMKO available
28.6
1.126
1. Ideal for magnetron and heater
loads
24.9
.980
2. Excellent heat resistance
• This satisfies UL coil insulation class B/
class F available
3. High insulation resistance
• Creepage distance and clearances be-
tween contact and coil: Min. 8 mm .315
inch
12.4
28.6
1.126
.488
24.9
.980
• Surge withstand voltage: Min. 10,000V
mm inch
SPECIFICATIONS
Contact
Characteristics
Arrangement
1 Form A
100 mΩ
Max. operating speed
(at rated load)
Initial insulation resistance*1
20 cpm
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Min. 1,000 MΩ (at 500 V DC)
Contact material
Silver alloy
16 A 277 V AC
Between open
contacts
1,000 Vrms for 1 min.
Initial breakdown
voltage*2
Nominal switch-
ing capacity
Between con-
tacts and coil
4,000 Vrms for 1 min.
Min. 10,000 V
Max. switching
power
4,432 V A
277 V AC
16 A
Initial surge voltage between contact
Rating
(resistive load)
and coil*3
Operate time*4
Max. switching
voltage
Max. 20ms
(at nominal voltage) (at 20°C 68°F)
Max. switching
current
Max. 20ms
Max. 25ms
(200 mW type)
Release time (with diode)*4
(at nominal voltage) (at 20°C 68°F)
Mechanical
(at 180 cpm)
2 × 106
Expected life
(min. operations)
Temperature rise (at nominal voltage)
(resistance method, contact current
16 A, 20°C 68°F)
Max. 55°C
Max. 45°C
(200 mW type)
Electrical
(at 20 cpm)
(Resistive load)
105
Functional*5
Destructive*6
Min. 200 m/s2{20 G}
Min. 1,000 m/s2{100 G}
Shock resistance
Coil
10 to 55Hz
at double amplitude of 1.5mm
Type
Standard
400 mW
High sensitive
200 mW
Functional*7
Vibration
Nominal operating power
resistance
10 to 55Hz
at double amplitude of 1.5mm
Destructive
Remarks
Specifications will vary with foreign standards certification ratings.
* Measurement at same location as “Initial breakdown voltage” section.
* Detection current: 10mA
* Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
* Excluding contact bounce time.
* Half-wave pulse of sine wave: 11 ms; detection time: 10 µs
* Half-wave pulse of sine wave: 6 ms
* Detection time: 10 µs
Conditions for operation,
–40°C to +85°C
–40°F to +185°F
1
Ambient temp.
8
transport and storage
*
2
(Not freezing and condens-
ing at low temperature)
3
Humidity
5 to 85% R.H.
4
Unit weight
Approx. 17 g .60 oz
5
6
7
8
* Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
TYPICAL APPLICATIONS ORDERING INFORMATION
• Microwave ovens
Ex.
A
LE
1
2
B
12
• Refrigerators
• OA equipment
Product name Contact arrangement
Terminal shape
Coil insulation class Coil voltage, V DC
LE
1: 1 Form A
7: 1 Form A
(200 mW)
2: TMP type/PCB side three terminals
(includes one dummy terminal)
3: TMP type/PCB side three terminals
4: TMP type/PCB side four terminals
5: PCB type (No tab terminals)
B: Class B insulation
F: Class F insulation
05: 5 18: 18
06: 6 24: 24
09: 9 48: 48
12: 12
UL/CSA, TÜV, VDE approved type is standard.
Note: Standard packing; Carton: 100 pcs. Case 500 pcs.
43