5秒后页面跳转
ALD12A48N-6S PDF预览

ALD12A48N-6S

更新时间: 2024-12-01 06:36:55
品牌 Logo 应用领域
艾默生 - EMERSON-NETWORKPOWER /
页数 文件大小 规格书
2页 325K
描述
High Efficiency

ALD12A48N-6S 数据手册

 浏览型号ALD12A48N-6S的Datasheet PDF文件第2页 
Total Power:  
Input Voltages:  
No. of Outputs:  
60W  
48  
Single  
25 Amps  
ALD25  
Electrical Specs  
Input  
Input Range  
Input Surge  
Efficiency  
36 to 75 VDC  
100V /100ms  
88%@1.8V (Typical)  
Output  
Line Regulation  
0.1%VO  
0.1%VO  
Load Regulation  
Noise/Ripple1  
35mV Typ  
Remote sense  
Up to 10% of Vo  
Transient Response  
3%Vo (typ) deviation  
50% to 75% Load change  
80µs settling time (typ)  
Special Features  
Overvoltage Protection  
125% VO typ (autorecovery)  
High Efficiency  
-40°C to +85°C Ambient Air Operation  
1.30” x 0.9" x 0.35" TH or SMT package  
High capacitive load limit on start-up  
Industry standard feature sets: UVLO, OVP,  
OCP, OTP, On/Off Enable, Remote Sense,  
Output Trim  
Over Current protection 115% IO typ (autorecovery)  
Over Temperature  
Protection  
Switching Frequency  
Isolation Voltage  
115ºC average PCB temperature  
(autorecovery)  
Fixed Frequency  
1500 Vdc  
Basic Insulation  
Regulation to zero load  
Control  
Voltage Adjust  
Enable  
Fixed frequency switching  
90 to 110% Vo  
TTL compatible  
(Positive or Negative enable options)  
EU Directive 2002/95/EC compliant for RoHS  
Environmental  
Ambient air operating temperature range:  
-40°C to +85°C  
Storage temperature: -40°C to +125°C  
Overtemperature protection: 115°C PCB  
temperature (Typical)  
MTBF: > 1 million hours  
Safety  
UL,cUL 60950-1  
TUV EN60950-1  
1
North America (USA): 1-888-41-ASTEC  
Europe (UK): 44 (1384) 842-211Asia (HK): 852-2437-9662