VDE
without screw
pending terminal socket
pending
SLIM AND COMPACT RELAY
FOR WIDER APPLICATIONS
HN-RELAYS
FEATURES
• Slim and compact size
• Slim screw terminal socket
Utilizes relay-securing hook for easy relay
removal.
20% more compact (width and height)
than existing model* (with the condition of
screw terminal socket for DIN rail)
*Compared with our HJ relay.
• High reliability and reasonable price
Uses gold-flashed contacts for highly
reliable contact.
TYPICAL APPLICATIONS
Control panels
Machine tools
• Environmentally friendly
Forming machines
Commercial equipment
Agricultural machines
Vending machines
In consideration of the environment,
cadmium-free contacts are used. Also
supports lead-free.
(Both relays and screw terminal socket.)
SPECIFICATIONS
Contacts
Characteristics
Contact arrangement
2 Form C
50mΩ
Max. operating speed
Initial insulation resistance*1
20 cpm (at max. rating)
Min. 1,000 MΩ at 500 V DC
1,000 Vrms for 1 min.
3,000 Vrms for 1 min.
5,000 Vrms for 1 min.
Max. 15 ms*4
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Between open contacts
Initial
Contact material
Gold-flashed silver alloy
breakdown Between contact sets
Nominal switching capacity 5A 250V AC, 5A 30V DC
voltage*2
Between contact and coil
Max. switching power
Max. switching voltage
Max. switching current
Min. switching current*9
1,250 VA, 150W
250V AC, 30V DC
5 A
Rating
(resistive
load)
Operate time*3 (at nominal voltage)
Release time (without diode)*3
(at nominal voltage)
Max. 10 ms*4
1V 1 mA
AC: 107
DC: 2×107
Temperature rise, max. (at 70°C)
(at nominal voltage)
60°C
Mechanical
(at 300 cpm)
Expected life
(min.
operations)
Functional*5
Destructive*6
Min. 100 m/s2 {10 G}
Min. 1,000 m/s2 {100 G}
Shock resistance
Electrical (at 20 cpm)
(resistive load)
105
10 to 55 Hz at double
amplitude of 1.5 mm
Functional*7
Vibration resistance
Coil
10 to 55 Hz at double
amplitude of 1.5 mm
Destructive
Nominal operating power
0.53W 0.9VA
Remarks
Conditions for operation,
transport and storage*8
(Not freezing and
condensing at low
temperature)
Ambient
temp.
–40°C to +70°C
–40°F to +158°F
*
*
*
*
*
*
*
*
*
*
Specifications will vary with foreign standards certification ratings.
1
2
3
4
5
6
7
8
9
Measurement at same location as “Initial breakdown voltage” section
Detection current: 10mA
Excluding contact bounce time
For the AC coil types, the operate/release time will differ depending on the phase.
Half-wave pulse of sine wave: 11ms; detection time: 10µs
Half-wave pulse of sine wave: 6ms
Humidity
5 to 85% R.H.
Unit weight
Approx. 17g .60 oz
Detection time: 10µs
Refer to 4. Conditions for operation, transport and storage mentioned in NOTES
This value can change due to the switching frequency, environmental conditions
and desired reliability level, therefore it is recommended to check this with the
actual load.
ORDERING INFORMATION
Ex. AHN
Contact arrangement
2: 2 Form C
Terminal arrangement
Type classification
0: Standard
1: With LED indication
2: With diode
Coil voltage
1: AC plug-in type
2: DC plug-in type
05: 5, 06: 6, 12: 12, 24: 24, 48: 48 V
X0: 100/110 V AC, 100 V DC
X1: 110/120 V AC, 110 V DC
3: With LED indication, diode
Y0: 200/220 V AC, Y2: 220/240 V AC
Note: Products conform to UL/C-UL and VDE, as standard (pending).
HN RELAY
ASCT1B263E ’03.4
New