xppower.com
220 Watts
AFE220 Series
•
•
•
•
•
•
•
Energy Efficiency Level V
CEC2008, EISA2007 & ErP Compliant
High Power Density
Single Outputs from 12 V to 48 V
High Efficiency
Low Earth Leakage Current
3 Year Warranty
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
• 2.1 A rms at 115 VAC,
1.1 A rms at 230 VAC
• 110 A typical at 115 VAC,
cold start +25 °C
• 0.95 typical at full load, 230 VAC
Efficiency
• See table
• Level V
• 3000 VAC Input to Output
1500 VAC Input to Ground
Output return is electrically connected to
Input Earth
Energy Efficiency
Isolation
Inrush Current
Power Factor
Switching Frequency
• PFC: 40 kHz typical
PWM: 120-160 kHz
Earth Leakage Current • 400 µA max at 264 VAC, 60 Hz
Input Protection
3
Power Density
MTBF
• 5.0 W/In
• Internal T4 A/250 V fuse
• <0.5 W
• >100 kHrs to MIL-HDBK-217F
at 25 °C, GB
Standby Power
Consumption
Environmental
Output
Operating Temperature • 0 °C to 60 °C, derate from 100% power at
Output Voltage
• See table
• Not user-adjustable
40 °C to 50% power at 60 °C
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Operating Humidity
• 10-95% RH, non-condensing
•
2% maximum at 100% load
Storage Temperature • -20 °C to +80 °C
• No minimum load required
• 3 s maximum at 100 VAC
• 5 ms minimum at 100 VAC
Operating Altitude
Shock
• 3000 m
• 30 g, 10 ms on 3 axes
• 5-100 Hz, 2.31 m/s , 20 mins, 3 axes
Start Up Delay
Hold Up Time
2
Vibration
Line Regulation
Load Regulation
Transient Response
•
0.5% maximum
• See table
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
EMC & Safety
Emissions
• EN55022, Class B conducted
EN55022, Class B radiated
Ripple & Noise
• 2% max pk-pk (see note 1)
Harmonic Currents
Voltage Flicker
ESD Immunity
• EN61000-3-2, Class A
• EN61000-3-3
• EN61000-4-2, 8 kV contact,
15 kV air discharge Perf Criteria A
Overvoltage Protection • 110-140% Vnom, recycle input to reset
Overtemperature
Protection
• Unit shuts down, auto recovery
Overload Protection
• 110-150%, auto recovery
Radiated Immunity
EFT/Burst
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
Short Circuit Protection • Trip and restart (Hiccup mode)
Temperature
Coefficient
• 0.04%/°C maximum
Surge
• EN61000-4-5, installation class 3
Perf Criteria A
Conducted Immunity
Magnetic Field
• EN61000-4-6, 3 Vrms Perf Criteria A
• EN61000-4-8, 1 A/m Perf Criteria A
Dips & Interruptions
• EN55024, 100% for 10 ms,
30% 500 ms, 100% 5000 ms,
Perf Criteria A, A, B High line,
A,B,B Low line
Safety Approvals
• EN60950-1, UL60950-1,
CSA22.2 No. 60950-1 per cUL, CE Mark