6-25 Watts
AEP Series
xppower.com
•
•
•
•
•
•
•
Universal Input 90-264 VAC
Interchangeable Mains Plug, 10 Watt Models
Continous Short Circuit Protection
EN550022 Class B
Low Cost
6, 10, 15 and 25 Watt Versions
Non-standard Outputs Available
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
Efficiency
• Typically 70% for 6 W,
75% for 10 and 15 W,
80% for 25 W
• 47-63 Hz
• 0.2/0.09 A at 115/230 VAC (6W & 10W)
0.3/0.15 A at 115/230 VAC (15W)
0.5/0.3 A at 115/230 VAC (25W)
Isolation
• 3000 VAC Input to Output
• 60 kHz 10 kHz
Switching Frequency
MTBF
Inrush Current
• 15/30 A max at 115/230 VAC (6W & 10W)
25/50 A max at 115/230 VAC (15W & 25W)
• >230 kHrs, MIL-HDBK-217F
Environmental
Output
Operating Temperature • 0 ˚C to +40 ˚C
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
• See tables
Storage Temperature
• -20 ˚C to +85 ˚C
• See tables
EMC & Safety
• No minimum load requirement
• 6 W 100 ms,
10 W 240 ms,
15 W 270 ms,
25 W 280 ms
Emissions
• EN55022, level B
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-4-2, level 2 Perf Criteria B
• EN61000-4-3, level 2 Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria B
• EN61000-4-5, level 2 Perf Criteria B
• EN61000-4-6, level 2 Perf Criteria B
Hold Up Time
• 10 ms typical at 115 VAC,
60 ms typical at 230 VAC
Surge
Conducted Immunity
Dips & Interruptions
Line Regulation
Load Regulation
Ripple & Noise
• See tables
• EN61000-4-11, 5 % UT 10 ms, Perf
Criteria B, 70 % UT 500 ms,
Perf Criteria C
• See tables
• 1 % pk-pk max (see note 2)
Overvoltage Protection • 125% typical
Safety Approvals
• EN60950, UL1950,
CSA C22.2 No.234 cUL
Overload Protection
• Trip and restart (Hiccup mode)
Short Circuit Protection • Continuous (auto recovery)