PRTD Conditioning Circuit
and Temperature Controller
a
ADT70*
FUNCTIONAL BLOCK DIAGRAM
FEATURES
PRTD Temperature Measurement Range
Typical IC Measurement Error ؎1؇C
Includes Two Matched Current Sources
Rail-to-Rail Output Instrumentation Amp
Uncommitted, Rail-to-Rail Output Op Amp
On-Board ؉2.5 V Reference
Temperature Coefficient ؎25 ppm/؇C
؉5 V or ؎5 V Operation
Supply Current 4 mA Max
NULLA
NULLB
BIAS 2.5V
REFOUT
ADT70
+V
S
OUT
OA
OA
MATCHED
CURRENT
SOURCES
I
I
OUTA
+IN
OA
OUTB
2.5V
REF
؊IN
10 A Max in Shutdown
+IN
IA
APPLICATIONS
INST
AMP
SHUT-
DOWN
SHUTDOWN
Temperature Controllers
Portable Instrumentation
Temperature Acquisition Cards
؊IN
IA
RGA RGB GND
OUT
IA
AGND ؊V
DGND
S
SENSE
GENERAL DESCRIPTION
The ADT70 provides excitation and signal conditioning for
resistance-temperature devices (RTDs). It is ideally suited for
1 kΩ Platinum RTDs (PRTDs), allowing a very wide range of
temperature measurement. It can also easily interface to 100 Ω
PRTDs. Using a remote, low cost thin-film PRTD, the ADT70
can measure temperature in the range of –50°C to +500°C.
With high performance platinum elements, the temperature
change can be extended to 1000°C. Accuracy of the ADT70
and PRTD system over a –200°C to +1000°C temperature
range heavily depends on the quality of the PRTD. Typically
the ADT70 will introduce an error of only ±1°C over the
transducer's temperature range, and the error may be trimmed
to zero at a single calibration point.
PIN CONFIGURATIONS
20-Lead P-DIP
(N Suffix)
–V
+V
V
20
19
18
17
16
1
2
S
S
AGND
OUT OA
V
–IN
3
REFOUT
BIAS
OA
+IN
4
OA
NULLA
NULLB
ADT70
5
SHUTDOWN
TOP VIEW
DGND
6
(Not to Scale) 15
V
I
14
13
12
7
OUT IA
OUTA
GND SENSE
RGB
I
8
OUTB
The ADT70 consists of two matched 1 mA (nominal) current
sources for transducer and reference resistor excitation, a preci-
sion rail-to-rail output instrumentation amplifier, a 2.5 V refer-
ence and an uncommitted rail-to-rail output op amp. The
ADT70 includes a shutdown function for battery powered
equipment, which reduces the quiescent current from 4 mA to
less than 10 µA. The ADT70 operates from either single +5 V
or ±5 V supplies. Gain or full-scale range for the PRTD and
ADT70 system is set by a precision external resistor connected
to the instrumentation amplifier. The uncommitted op amp may
be used for scaling the internal voltage reference, providing a
“PRTD open” signal or “over-temperature” warning, a heater
switching signal, or other external conditioning determined by
the user.
–IN
IA
9
RGA
+IN
IA
10
11
a
20-Lead SOIC
(R Suffix)
–V
S
+V
20
19
18
17
16
15
14
13
12
11
1
2
S
AGND
V
OUT OA
V
–IN
+IN
3
REFOUT
OA
OA
BIAS
4
NULLA
NULLB
5
ADT70
TOP VIEW
(Not to Scale)
SHUTDOWN
DGND
6
V
The ADT70 is specified for operation from ؊40°C to ؉125°C
and is available in 20-lead DIP and SO packages.
I
7
OUT IA
OUTA
GND SENSE
RGB
I
8
OUTB
9
؊ IN
؉ IN
IA
RGA
10
*
Patent pending.
IA
a
REV. 0
Information furnished by Analog Devices is believed to be accurate and
reliable. However, no responsibility is assumed by Analog Devices for its
use, nor for any infringements of patents or other rights of third parties
which may result from its use. No license is granted by implication or
otherwise under any patent or patent rights of Analog Devices.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781/329-4700
Fax: 781/326-8703
World Wide Web Site: http://www.analog.com