5.7 kV rms, Signal Isolated, High Working Voltage,
CAN FD Transceiver with ± ±5kV IꢀC ꢀSD
Data Sheet
ADM3058ꢀ
FEATURES
FUNCTIONAL BLOCK DIAGRAM
V
V
DD2
DD1
5.7 kV rms signal isolated CAN FD transceiver
1500 V peak and dc working voltage to DIN VDE 0884-11
1.7 V to 5.5 V supply and logic side levels
4.5 V to 5.5 V supply on bus side
ISO 11898-2:2016-compliant CAN FD
Data rates up to 12 Mbps for CAN FD
Low maximum loop propagation delay: 155 ns
Extended common-mode range: 25 V
Bus fault protection (CANH, CANL): 40 V
ESD protection on the CANH and CANL bus pins
≥ 8 kV IEC 61000-4-2 contact discharge
≥ 15 kV IEC 61000-4-2 air discharge
ADM3058E
CAN
TRANSCEIVER
DOMINANT
TIMEOUT
DIGITAL ISOLATOR
TXD
RXD
CANH
CANL
THERMAL
SHUTDOWN
Passes EN 55022, Class B by 6 dB
Safety and regulatory approvals (pending)
UL: 5700 V rms for 1-minute per UL 1577
CSA Component Acceptance 5A at 5.7 kV rms
IEC 60601 and IEC 61010
GND
GND
2
1
Figure 1.
VDE Certificates of Conformity
DIN VDE V 0884-11 (VDE V 0884-11):2017-01
V
IORM = 1500 V peak
High common-mode transient immunity: >50 kV/μs
Industrial operating temperature range: −40°C to +125°C
APPLICATIONS
CANOpen, DeviceNet, and other CAN bus implementations
Industrial automation
Process control and building control
Transport and infrastructure
GENERAL DESCRIPTION
The ADM3058E is a 5.7 kV rms isolated controller area
network (CAN) physical layer transceiver with a high perfor-
mance, basic feature set. The ADM3058E fully meets the CAN
flexible data rate (CAN FD) ISO 11898-2:2016 requirements and is
further capable of supporting data rates as high as 12 Mbps.
regulatory approvals (pending) for a 5.7 kV rms withstand voltage
and a 1500 V peak working voltage ensure that the ADM3058E
meets application isolation requirements.
Low loop propagation delays and the extended common-mode
range of ±25 V support robust communication on longer bus
cables. Dominant timeout functionality protects against bus
lock up in a fault condition, and current limiting and thermal
shutdown features protect against output short circuits. The
CAN bus input and output pins are protected to ±±0 V against
accidental connection to a +2± V bus supply. The device is fully
specified over the −±0°C to +125°C industrial temperature range.
The device employs Analog Devices, Inc., iCoupler® technology
to combine a 2-channel isolator and a CAN transceiver into a
single small outline integrated circuit (SOIC) surface-mount
package. The ADM3058E is a fully isolated solution for CAN
and CAN FD applications. The ADM3058E provides isolation
between the CAN controller and physical layer bus. Safety and
Rev. A
Document Feedback
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice.
No license is granted by implication or otherwise under any patent or patent rights of Analog
Devices. Trademarks and registeredtrademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
Technical Support
©2020 Analog Devices, Inc. All rights reserved.
www.analog.com