1
Related Products: Motor Operated Auto Drain
Series ADM200
Model/Specifications
Model
ADM200-
-
Reliably discharges even highly
viscous drainage
Highly resistant to dust and highly viscous
drainage, the valve opens and closes
reliably to discharge the drainage.
Fluid
Air
1.0 MPa
1.5 MPa
Max. operating pressure
Proof pressure
–5 to 60°C (No freezing)
1 cycle in a minute (Standard)
2 sec./cycle (Standard)
Ambient and fluid temperature
∗
Operating cycle
Large drain discharge capacity
With a large discharge port, a large
amount of drainage can be discharged in a
single operation.
Operating time
Power source
Power consumption
100, 200 VAC50 Hz, Other
60
4 W
3
1
2
IN: Rc
OUT: Rc
550 g
,
8
Port size
3
8
Elimination of residual drainage from inside
of the tank and pipes prevents the
generation of foreign matter as a result of
dried rust or drainage, which could
adversely affect the equipment located on
the outlet side.
Weight
∗ If the operating cycle is twice in a minute (op. time 2 sec. x 2) operating time is 4 sec. each minute.
the tank. Failure to observe this precaution
could lead to malfunctions.
2. Install this product, so that its drain port
faces down. Failure to observe this
precaution could lead to malfunctions.
Precautions
Be sure to read before handling.
Refer to pages 14-21-3 to 4 for Safety
Instructions and Common Precau-
tions on the products mentioned in
this catalog, and refer to pages 14-14-
6 to 8 for Precautions on every series.
Low power consumption: 4 W
A long pipe can also be connected to the
discharge port.
Caution
It can be connected directly to
compressor.
a
1. Provide a stop valve before ADM200 to
facilitate maintenance and inspection.
Maintenance
Mounting
Caution
1. If the valve becomes clogged with debris,
press the manual button to flush out the
debris. Failure to observe this precaution
could lead to malfunctions.
Warning
1. Install this product after discharging the
drainage that has already accumulated in
Mounting Example
Compressor
Aftercooler
Air tank
Main line filter
Air dryer
How to Order
ADM200
Port size
Symbol
IN
OUT
3
3
03
8
8
1
2
3
8
04
Construction/Dimensions
Voltage
50
50
50
50
50
1
2
3
4
5
6
7
100 VAC
200 VAC
240 VAC
110 VAC
220 VAC
Hz
Hz
Hz
Hz
Hz
60
60
60
60
60
Set screw
24 VDC
12 VDC
Operating time/
Applicable compressor
Manual button
Nil
4
6
2 sec/min (1 cycle/min) /3.7 to 37 kW
4 sec/min (2 cycle/min) /37 to 75 kW
6 sec/min (3 cycle/min) /75 to 110 kW
8 sec/min (4 cycle/min) /220 to 370 kW
Component Parts
Replacement Parts
8
No. Description
Material
ADC12
ADC12
Note
Chrome treated
Chrome treated
No. Description
Material
Part no.
q
eNote) Motor
—
812PG-voltage
Operating time
201324 (Nil)
201325 (4)
Body
Cap
w
r
Cam
SCS13
201326 (6)
201327 (8)
t
y
Valve assembly C3604B
O-ring
20137-1A
S-16
NBR
Note) Motor port no. in the case of 100 VAC: 812PG-100VAC
14-20-50