AD9371
Data Sheet
Parameter
Symbol
Min
Typ
Max
Unit
Test Conditions/Comments
Input Third-Order Intercept Point IIP3
Maximum ORx gain,
IM3 1 MHz offset from LO
700 MHz LO
2600 MHz LO
3500 MHz LO
5500 MHz LO
22
22
18
18
dBm
dBm
dBm
dBm
Input Second-Order Intercept
Point
IIP2
Maximum ORx gain, IM2
1 MHz offset from LO
700 MHz LO
2600 MHz LO
3500 MHz LO
5500 MHz LO
Image Rejection
700 MHz LO
2600 MHz LO
3500 MHz LO
5500 MHz LO
Input Impedance
65
65
65
60
dBm
dBm
dBm
dBm
After online tone calibration
65
65
65
65
200
dB
dB
dB
dB
Ω
Differential
Tx1 to ORx1 Signal and Tx2 to
ORx2 Signal Isolation
700 MHz LO
2600 MHz LO
3500 MHz LO
5500 MHz LO
70
70
70
70
dB
dB
dB
dB
Tx1 to ORx2 Signal and Tx2 to
ORx1 Signal Isolation
700 MHz LO
2600 MHz LO
3500 MHz LO
70
70
70
70
dB
dB
dB
dB
5500 MHz LO
SNIFFER RECEIVER (SnRx)
Center Frequency
Gain Range
300
0
6000
52
MHz
dB
Analog Gain Step
BW Ripple
1
dB
dB
0.5
20 MHz RF BW, compensated
by programmable FIR filter
Rx Bandwidth
Rx Alias Band Rejection
20
MHz
dB
60
Due to digital filters
Maximum Recommended Input
Power8
−26
dBm
Input is a CW7 signal at 0 dB
attenuation setting
Noise Figure
NF
Maximum gain at
SnRx port, matching losses
de-embedded, gain control
limited to the first 20 steps
700 MHz LO
2600 MHz LO
3500 MHz LO
5500 MHz LO
5
5
7
12
dB
dB
dB
dB
Input Third-Order Intercept Point IIP3
Maximum gain, IM3 1 MHz
offset from LO, gain control
limited to the first 20 steps
700 MHz LO
2600 MHz LO
3500 MHz LO
5500 MHz LO
1
1
1
3
dBm
dBm
dBm
dBm
Rev. A | Page 6 of 60