Discontinued as of August 31, 2010
CY (ACY)
HIGH CAPACITY
PC BOARD TYPE
AUTOMOTIVE RELAY
CY RELAYS (ACY)
FEATURES
TYPICAL APPLICATIONS
1. 30 A nominal switching capacity
Capable of 30 A resistance load
switching which is twice that of its
predecessor of the same size
(JSM Relay)
• Defoggers (for standard type)
• Heaters (for standard type)
• Headlights (for H/L type)
• Fog lamps (for H/L type)
16
.630
22
.866
16.4
.646
2. 30 A maximum carrying current
30 A/1 hour, 35 A/2 minutes at 20°C
25 A/1 hour, 30 A/2 minutes at 85°C
(for 450mW type, 14 VDC)
mm inch
3. H/L type ideal for lamp loads
A H/L type is also available in which
headlight load switching is possible
(60 W × 2 lamps).
4. Designed to be environmentally
friendly
With cadmium-free contacts and lead-
free solder, environmentally harmful
substances are not used.
Compliance with RoHS Directive
SPECIFICATIONS
Contact
Characteristics
1 Form C, 1 Form A,
1 Form A for H/L type
Max. operating speed
(at nominal switching capacity)
Arrangement
6cpm
Contact material
Ag alloy (Cadmium free)
Min. 100MΩ
Initial insulation resistance
(at 500 V DC)
Initial contact resistance (Initial)
(By voltage drop 6 V DC 1 A)
Typ. 8 mΩ (N.O.)
Typ. 6 mΩ (N.C.)
Between open contacts
500 Vrms for 1min.
Initial breakdown
voltage*3
Nominal
switching
capacity
Between contacts and coil 1,500 Vrms for 1min.
N.O.: 30 A 14 V DC
N.C.: 15 A 14 V DC
Operate time*4
(at nominal voltage) (at 20°C 68°F)
Release time*4
(at nominal voltage) (at 20°C 68°F)
Max. 10ms (initial)
N.O.:
Max. 10ms (initial)
For 450m W
30 A/1 hour, 35 A/2 minutes at 20°C 68°F
25 A/1 hour, 30 A/2 minutes at 85°C 185°F
For 640m W
25 A/1 hour, 35 A/2 minutes at 20°C 68°F
20 A/1 hour, 30 A/2 minutes at 85°C 185°F
N.C.:
For 450m W and 640m W
20 A/1 hour, 25 A/2 minutes at 20°C 68°F
15 A/1 hour, 20 A/2 minutes at 85°C 185°F
Functional*5
Min. 100 m/s2{10 G}
Destructive*6 Min. 1,000 m/s2{100 G}
Shock resistance
Rating
Max. carrying
current
10 Hz to 100 Hz,
Functional*7
Min.44.1 m/s2 {4.5 G}
Vibration resistance
10 Hz to 500 Hz,
Destructive*8
Min.44.1 m/s2 {4.5 G}
Conditions in case of opera-
tion, transport and storage*9
(Not freezing and condensing
at low temperature)
Ambient
temp
–40°C to +85°C
–40°F to +185°F
Min. switching
capacity#1
1 A 12 V DC
Min. 107
Humidity
5% R.H. to 85% R.H.
Approx. 12g .42 oz
Mechanical
(at 120 cpm)
Expected
life (min.
operation)
Mass
Remarks
Electrical
(at rated load)
Standard type (resistive load): Min. 105*1
H/L type (lamp load): Min. 105*2
1
*
*
At nominal switching capacity, operating frequency: 1s ON, 9s OFF
At 60 W x 2 lamps (Inrush: 70 A, Steady: 10 A 14 VDC), operating frequency: 1s
ON, 14s OFF
2
Coil
3
4
5
6
7
8
*
*
*
*
*
*
Detection current: 10mA
Excluding contact bounce time.
450m W
(for Pick-up voltage: 7.2 V, Standard type)
640m W
(for Pick-up voltage: 6.5 V, Standard type)
640m W
Half-wave pulse of sine wave: 11 ms; detection time: 10 µs
Half-wave pulse of sine wave: 6 ms
Detection time: 10 µs
Nominal operating power
Time of vibration for each direction;
X, Y direction: 2 hours
Y
X
(for Pick-up voltage: 7.2 V, H/L type)
Z direction: 4 hours
Z
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
9
*
Refer to Conditions for operation, transport and storage mentioned in AMBIENT
ENVIRONMENT.
Please inquire if you will be using the relay in a high temperature atmosphere
(110°C 230°F).
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.