40-60 Watts
ACS Series
xppower.com
•
•
•
•
•
•
•
Low Cost
Small Size
Universal Input
Rugged Design
High MTBF
International Safety Approvals
Covered Versions Available
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC (110-370 VDC)
Efficiency
Isolation
• See tables
• 47-63 Hz
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
• ACS40: 0.45 A rms at 230 VAC
ACS60: 0.60 A rms at 230 VAC
Switching Frequency
MTBF
• 50-70 kHz
Inrush Current
• Cold start at 25 ºC: 25 A at 115 VAC,
50 A at 230 VAC
• 230 kHrs per MIL-HDBK-217F
Earthing
• Class I
Environmental
Output
Operating Temperature • 0 ºC to +70 ºC, derate from full load at
+50 ºC to half load at +60 ºC.
Output Voltage
Output Voltage Trim
Hold Up Time
• See table
Reduce both temperatures by 10 ºC when
cover is fitted
•
5ꢀ
• 8 ms typical at full load
Storage Temperature
• -40 ºC to +85 ºC
Line Regulation
Load Regulation
Ripple & Noise
• 0.5ꢀmax at full load
• 1.0ꢀ max at 10ꢀ load to full load
• 1ꢀ max pk-pk, 20MHz BW
EMC & Safety
Emissions
• FCC20780 Level B, CISPR22 (EN55022),
level B conducted
Overvoltage Protection • Typically 130ꢀ of max output
Overcurrrent Protection • 120ꢀ typical
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 10 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 10 V Perf Criteria y
• EN60950, UL1950, CSA22.2 No. 234
Surge
Conducted Immunity
Safety Approvals