Series
ACP100E
Low Cost, 1W
Ultra-Miniature
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
• 1W Output Power
Parameter
Conditions
Min.
Typ.
Max.
Units
5 VDC Input 4.50
5.0
5.50
• Miniature Low Profile Case
• DCP01 Series Replacement
• 1,500 VDC Isolation
• Short Circuit Protected
• >3.5 MHour MTBF
Input Voltage Range
VDC
12 VDC Input 10.80 12.0 13.20
Internal Capacitor
Input Filter
Output
Parameter
Conditions
Min.
Typ.
Max.
Units
%
Output Voltage Accuracy
Line Regulation
Load Regulation, See Note 1
3.0
• SMT Ver Available (LCP100E)
• LOW, LOW COST!!
For Vin Change of 1%
1.2
%
See Model Selection Guide
50% Iout
20
50
Ripple & Noise (20 MHz), See Note 3
mV P - P
%/°C
100% Iout
75
Temperature Coefficient
Output Short Circuit, See Note 4
General
0.03
Continuous (Autorecovery)
Parameter
Conditions
Conditions
Min.
60 Seconds 1,500
500 VDC 1,000
100 kHz, 1V
Typ.
Max.
Units
VDC
M
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
25
pF
100
kHz
Min.
Typ.
Max.
+85
Units
°C
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
-40
+25
+100
+125
°C
-55
°C
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
0.77 x 0.30 x 0.18 Inches (19.5 x 7.62 x 4.5 mm)
Non-Conductive Black Plastic (UL-94V0)
0.05 Oz (1.4g)
Case Material
Weight
MicroPower Direct
292 Page Street
Suite D
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
Stoughton, MA 02072
USA
MTBF
MIL HDBK 217F, 25°C, Gnd Benign
3.5
MHours
Shock & Vibration, See Note 5
Absolute Maximum Ratings
Parameter
Meets MIL-STD-202F, IEC68-2-6
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Conditions
Min.
Typ.
Max.
9.0
Units
VDC
°C
5 VDC Input -0.7
12 VDC Input -0.7
Input Voltage Surge (1 Sec)
18.0
300
Lead Temperature
1.5 mm From Case For 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com