Data Sheet
ACML-7400, ACML-7410, and ACML-7420
3.3V/5V 100-MBd High-Speed CMOS Digital
Isolator
Description
Features
®
The Broadcom ACML-7400, ACML-7410, and ACML-
Dual supply voltage compatible – 3.3V and 5V
7420 are multi-channel, high-speed CMOS digital isolators.
Using magnetic coupling through a thick insulation barrier,
the isolators enable high speed transmissions without
compromise in isolation performance. These isolators
consume low power even at high data rates, yet provide
excellent transient immunity performance in compact
surface-mount packages. The devices are qualified to a
maximum propagation delay of 36 ns and a maximum pulse
width distortion of 3 ns. They are capable of running at a 100
MBaud data rate.
Wide operating temperature range (-40° C to +105° C)
Support high speed data rate of at least 100 MBd
Lower power consumption – 15 mA per channel typical
Low propagation delay: 36 ns max.
Low propagation delay skew
– Channel-to-channel: 4 ns max.
– Part-to-part: 8 ns max.
Low pulse width distortion: 3 ns max.
Safety and regulatory approvals
UL Recognised
ACML-7400, ACML-7410 ,and ACML-7420 are available in
16-pin SOIC wide-body packages. They operate at dual
3.3V/5V supply voltages. The DC and timing specifications
are specified over the temperature range of –40°C to
+105°C. ACML-7400, ACML-7410, and ACML-7420 are
built using CMOS input buff ers and CMOS output drivers to
eliminate the need for both input limiters and output pull-up
resistors. Refresh circuitry is built in to ensure DC-
correctness.
– 5600 V
for 1 min. per UL1577
RMS
– CSA Component Acceptance Notice #5
IEC 60950-1
– Basic Insulation, 800 V
max. working voltage
RMS
– Reinforced Insulation, 400 V
voltage
max. working
RMS
IEC 61010-1
– Basic Insulation, 800 V
max. working voltage
RMS
– Reinforced Insulation, 400 V
voltage
max. working
RMS
Applications
IEC 60601-1
Isolated data interfaces
– Two means of patient protection, 250 V
working voltage
max.
RMS
Data acquisition
Digital oscilloscopes
Power meters
– Two means of operator protectioin, 400 V
working voltage
max.
RMS
High speed video transmission
High common mode transient immunity: 75 kV/µs min
CMOS buffer input and output
DC correctness
.
Lead-free
CAUTION! It is advised that normal static precautions be taken in handling and assembly of this component to prevent
damage and/or degradation that may be induced by ESD. The components featured in this data sheet are not
to be used in military or aerospace applications or environments.
Broadcom
AV02-2675EN
January 23, 2018