VER : A_1
update : 2018.06.13
AC-DC ITE Switching Power Supply
ABR300U SERIES
300 Watts
KEY FEATURES
Standard
A Type
B Type
U Bracket Switching Power Supply
Universal Input: 90-264 VAC
Active P.F.C. Function, PF>0.9
300W Conduction Cooling
300W Convection with 18CFM FAN
Current Share Function
Over Current / Over Voltage /
.Over Temperature / Short Circuit Protection
3-Year Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
ABR300U-12S
ABR300U-24S
300W
ABR300U-28S
308W
ABR300U-48S
300W
Max Output Wattage (18CFM FAN) (W)
300W
300W
Max Output Wattage (Conduction Cooling)
(W)
Voltage
90-264 VAC
50/60 Hz (47-63 Hz)
Frequency (Hz)
Input
Current (Full load)
Inrush Current (<2ms)
Power Factor (typ.)
Voltage (V.DC.)
<4.0 A (100 VAC) / <2.0 A max. (200 VAC)
< 70 A max. (115 VAC) / < 90 A max. (230 VAC)
PF>0.95 (100 VAC) / PF>0.9 (230 VAC) at Full Load
12V
24V
28V
48V
Voltage Accuracy
Trim (V.DC)
±2%
11.04~ 12.96V
25
22.08 ~ 25.92V
12.5
25.76 ~ 30.24V
11
44.16 ~ 51.84V
6.25
Current (A) (max.)
Line Regulation (LL-HL) (typ.)
Load Regulation (10-100%) (typ.)
Minimum Load
±1%
±2%
±1%
Output
0%
Maximum Capacitive Load
Ripple & Noise (max.)
Efficiency (%) (at 230 VAC)
Remote Sensing
5000 uF
150mVp-p
88.5%
2500 uF
200mVp-p
89%
2500 uF
200mVp-p
89%
1250 uF
300mVp-p
90%
Provided
10 ms min.
Auto recovery
Auto recovery
Auto recovery
Hold-up Time (at 230 VAC)
Over Power Protection
Over Voltage Protection
Over Temperature
Protection
Isolation
Protection level 1 (nominal):Continuous, Auto recovery
Short Circuit Protection
Input-Output (V.AC)
Protection level 2 (instantaneous high current):Latch
3000V
Input-FG
(V.AC)
1500V
Output-FG .(V.AC)
Operating Temperature
Storage Temperature
Temperature Coefficient
Humidity
500V
-40°C…+65°C (with derating)
-40°C…+85°C
±0.05%/°C ( 0~50°C )
20~95% RH (Non condensing)
>200,000 h @ 25°C (MIL-HDBK-217F)
Environment
Physical
MTBF
Vibration
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes.
6.0 x 4.18 x 1.38 Inches (150.0 x 106.0 x 35.0 mm ) Tolerance 0.5 mm
560 g
Dimension (L x W x H)
Weight
Cooling Method
Conduction cooling
Safety
EMC
Agency Approvals
EMI (Conducted & Radiated Emission)
EMS (Noise Immunity)
CE (In Progress)
EN 55022 Conducted Class B & Radiated Class A (In Progress)
EN 55024、EN61000-4-2,3,4,5,6,8,11
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-