Limit Alarms (potentiometer adj.) A-UNIT

AAC-A3141-S 数据手册

 浏览型号AAC-A3141-S的Datasheet PDF文件第2页浏览型号AAC-A3141-S的Datasheet PDF文件第3页浏览型号AAC-A3141-S的Datasheet PDF文件第4页 
MODEL: AAC  
A2: 0 – 500 mV AC (Input resistance 100 kΩ min.)  
Limit Alarms (potentiometer adj.) A-UNIT  
A3: 0 – 1 V AC (Input resistance 100 kΩ min.)  
A4: 0 – 5 V AC (Input resistance 100 kΩ min.)  
A5: 0 – 10 V AC (Input resistance 100 kΩ min.)  
A6: 0 – 120 V AC (Input resistance 100 kΩ min.)  
A7: 0 – 150 V AC (Input resistance 100 kΩ min.)  
A8: Specify voltage (See INPUT SPECIFICATIONS)  
(0 % input must be 0 V.)  
AC ALARM  
Functions & Features  
• Providing SPDT relay outputs at preset AC current/voltage  
levels  
• True RMS sensing  
• Dual (Hi/Lo) trip  
• Energized or de-energized coil at a tripped condition  
selectable  
SETPOINT ADJUSTMENTS  
1: Single-turn screws  
• Deadband (hysteresis) adjustable  
• Enclosed relays  
• Relays can be powered 110 V DC  
• High-density mounting  
[2] SETPOINT 1 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
Typical Applications  
• Annunciator  
• Various alarm applications  
[3] SETPOINT 2 OUTPUT  
1: Hi (coil energized at alarm)  
2: Hi (coil de-energized at alarm)  
3: Lo (coil energized at alarm)  
4: Lo (coil de-energized at alarm)  
50  
(1.97)  
80  
(3.15)  
[4] POWER INPUT  
AC Power  
132  
(5.20)  
B: 100 V AC  
C: 110 V AC  
D: 115 V AC  
F: 120 V AC  
G: 200 V AC  
H: 220 V AC  
J: 240 V AC  
mm (inch)  
MODEL: AAC-[1]1[2][3]-[4][5]  
ORDERING INFORMATION  
• Code number: AAC-[1]1[2][3]-[4][5]  
Specify a code from below for each of [1] through [5].  
(e.g. AAC-AA111-B/Q)  
DC Power  
S: 12 V DC  
R: 24 V DC  
• Special input range (For codes AZ & A8)  
• Specify the specification for option code /Q  
(e.g. /C01/S01)  
V: 48 V DC  
P: 110 V DC  
[5] OPTIONS  
[1] INPUT  
blank: none  
Current  
/Q: With options (specify the specification)  
AA: 0 – 10 mA AC (Input resistance 100 Ω)  
AB: 0 – 50 mA AC (Input resistance 20 Ω)  
AC: 0 – 100 mA AC (Input resistance 10 Ω)  
AD: 0 – 500 mA AC (Input resistance 1 Ω)  
AZ: Specify current (See INPUT SPECIFICATIONS)  
(0 % input must be 0 mA.)  
SPECIFICATIONS OF OPTION: Q (multiple selections)  
COATING (For the detail, refer to M-System's web site.)  
/C01: Silicone coating  
/C02: Polyurethane coating  
/C03: Rubber coating  
Voltage  
TERMINAL SCREW MATERIAL  
/S01: Stainless steel  
A1: 0 – 100 mV AC (Input resistance 100 kΩ min.)  
AAC SPECIFICATIONS  
ES-2136 Rev.8 Page 1/4  
http://www.m-system.co.jp/  

与AAC-A3141-S相关器件

型号 品牌 获取价格 描述 数据表
AAC-A3141-S/Q MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
AAC-A3141-V MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
AAC-A3141-V/Q MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
AAC-A3142-B MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
AAC-A3142-B/Q MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
AAC-A3142-C MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
AAC-A3142-C/Q MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
AAC-A3142-D MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
AAC-A3142-D/Q MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT
AAC-A3142-F MSYSTEM

获取价格

Limit Alarms (potentiometer adj.) A-UNIT