APPLICABLE STANDARD
Operating
Storage
Temperature Range
-10 C to +60 C(2)
-55 C to +85 C(1)
Temperature Range
Operating
Storage
Relative humidity 85 % max (Not dewed)
Relative humidity 85 % max (Not dewed)
Humidity Range
Voltage
Humidity Range
Applicable Cable
Insulation
Rating
200 V AC
1 A
-
-
Current
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Marking
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
×
×
×
×
ELECTRIC CHARACTERISTICS
Contact Resistance
Insulation Resistance
Voltage Proof
100 mA (DC or 1000 Hz).
15 mΩ MAX .
×
×
×
-
-
-
500 V DC.
1000 MΩ MIN.
650 V AC for 1 min.
No flashover or breakdown.
MECHANICAL CHARACTERISTICS
Mechanical Operation
100 times insertions and extractions.
1) Contact Resistance: 20 m MAX.
×
×
-
-
2) No damage, crack and looseness of parts.
1) No electrical discontinuity of 1 s.
2) No damage, crack and looseness of parts.
Vibration
Frequency 10 to 55 Hz,
single amplitude : 0.75 mm,
2 h in 3 directions.
Shock
490 m/s2, duration of pulse 11 ms
at 3 times for 3 both axial directions.
×
-
ENVIRONMENTAL CHARACTERISTICS
Damp Heat
Exposed at 40 ± 2 C, 90 to 95 %, 96 h.
1) Contact Resistance: 20 m MAX.
×
×
-
-
(Steady state)
Rapid Change of
Temperature
2) Insulation Resistance: 1000 M MIN.
3) No damage, crack and looseness of parts.
Temperature
-55 → +5 to +35 → +85 → +5 to +35 C
Time
30 → 10 to 15 → 30 → 10 to 15 min.
Under 5 cycles.
Corrosion Salt Mist
Sulphur Dioxide
Exposed in 5 % salt water spray for 48 h.
1) Contact Resistance: 20 m MAX.
2) No heavy corrosion.
×
×
-
-
Exposed in 10 PPM for 96 h.
(Test standard: JEIDA 39)
Resistance to
Soldering Heat
No deformation of case of excessive
looseness of the terminals.
Solder bath:solder temperature,
260 ± 5 C for immersion,duration, 10 ± 1 s.
(JISC5402-12-4, JISC60068-2-20)
Soldering irons : 360C for 5 s MAX.
×
-
×
×
-
-
Solderability
Soldered at solder temperature, 245 ± 3 C,
for immersion duration, 3 s.
A new uniform coating of solder shall cover a
minimum of 95% of the surface
being immersed.
COUNT
DESCRIPTION OF REVISIONS
DIS-F-00004353
DESIGNED
HR.NAGAYASU
CHECKED
HT.YAMAGUCHI
NH.NAKATA
DATE
1
1
20190301
20170410
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
(1) Temperature rise included when energized.
(2) This storage indicates A long-term storage state
HT.YAMAGUCHI 20170410
HR.NAGAYASU 20170410
HR.NAGAYASU 20170410
For the unused product before the board mounted.
Unless otherwise specified, refer to IEC-60512.
Clerical corrections.
1
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
ELCX-375930-00-00
DRAWING NO.
PART NO.
CODE NO.
A3C-*P-2DSA(30)
SPECIFICATION SHEET
1
△
1/1
HIROSE ELECTRIC CO., LTD.
CL621
FORM HD0011-2-1