APPLICABLE STANDARD
OPERATING
STORAGE
-55 C TO 85 C(1)
-10 C TO +60 C(2)
TEMPERATURE RANGE
OPERATING
TEMPERATURE RANGE
STORAGE
40 % TO 80 %
200 V AC
1 A
40 % TO 70 %(2)
HUMIDITY RANGE
HUMIDITY RANGE
RATING
APPLICABLE CABLE
INSULATION
VOLTAGE
CURRENT
-
-
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
ACCORDING TO DRAWING.
GENERAL EXAMINATION
MARKING
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
×
×
×
×
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
100 mA (DC OR 1000 Hz).
15 mΩ MAX .
1000 MΩ MIN.
×
×
-
-
INSULATION RESISTANCE
500 V DC
VOLTAGE PROOF
650 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
×
-
MECHANICAL CHARACTERISTICS
CONTACT INSERTION AND
EXTRACTION FORCES
□0.5 ± 0.002 mm BY STEEL GAUGE.
INSERTION FORCE : 2.45 N MAX.
EXTRACTION FORCE: 0.25 N MIN.
1)CONTACT RESISTANCE: 20 m MAX.
2)NO DAMAGE, CRACK AND LOOSENESS
OF PARTS.
×
×
-
-
MECHANICAL OPERATION
100 TIMES INSERTIONS AND EXTRACTIONS.
1)NO ELECTRICAL DISCONTINUITY OF 1 s.
2)NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
VIBRATION
SHOCK
FREQUENCY 10 TO 55 Hz, AMPLITUDE : 1.5 mm,
2 h IN 3 DIRECTIONS.
×
×
-
-
2
490 m/s , DURATION OF PULSE 11 ms
FOR 3 TIMES IN 3 DIRECTIONS.
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40±2 C, 90 TO 95 %, 96 h.
1)CONTACT RESISTANCE:
20 m MAX.
×
×
-
-
2)INSULATION RESISTANCE: 1000 M MIN.
3)NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
(STEADY STATE)
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE
-65 → +15 TO +35 → +125 → +15 TO +35 C
TIME
30 → 10 TO 15 → 30 → 10 TO 15 min.
UNDER
5 CYCLES.
1)CONTACT RESISTANCE: 20 m MAX.
2)NO HEAVY CORROSION.
CORROSION SALT MIST
SULPHUR DIOXIDE
EXPOSED IN 5 % SALT WATER SPRAY FOR 48 h.
×
×
-
-
EXPOSED IN 10 PPM FOR 96 h.
(TEST STANDARD: JEIDA - 39)
RESISTANCE TO
SOLDERING HEAT
1)SOLDER BATH:SOLDER TEMPERATURE,
260±5℃ FOR IMMERSION,DURATION,10±1s.
2)SOLDERING IRONS : 350℃ FOR 3 s MAX.
NO DEFORMATION OF CASE OF EXCESSIVE
LOOSENESS OF THE TERMINALS.
×
×
×
-
-
-
SOLDERED AT SOLDER TEMPERATURE, 245±3C,
FOR IMMERSION DURATION, 2 s.
SOLDERABILITY
A NEW UNIFORM COATING OF SOLDER
SHALL COVER A MINIMUM OF 95 % OF
THE SURFACE BEING IMMERSED.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
HS.OKAWA
HT.YAMAGUCHI
MT.ITANO
15.06.04
15.06.04
15.06.04
15.06.04
(1)TEMPERATURE RISE INCLUDED WHEN ENERGIZED.
(2)THIS STORAGE INDICATES A LONG-TERM STORAGE STATE
FOR THE UNUSED PRODUCT BEFORE THE BOARD MOUNTED.
Unless otherwise specified, refer to MIL-STD-1344.
MT.ITANO
Note
Test
QT:Qualification Test
AT:Assurance Test
X:Applicable
ELC-081242-71-21
A3C-10DA-2DSC(71)
DRAWING NO.
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0 1/1
CL621-0534-5-71
△
FORM HD0011-2-1