300W Modified Sine Wave DC-AC Power Inverter
A-301/302-300 series
Features :
12V or 24V DC input
Power ON-OFF switch
Input voltage range: -15% ~ +25%
Output voltage regulation: 10%
Protections: Bat. Low alarm/Bat. Low shutdown/Over voltage/
Over temp./Output short/Input polarity reverse/Over load.
Output waveform: Modified sine wave
Cooling fan ON-OFF control
Topology: Microprocessor
Approvals: e13/ CE
1 year warranty
EMC
tested
LVD
tested
E
E
Germany
Germany
SPECIFICATION
ORDER NO.
A301-300-B2
A301-300-F3
A302-300-B2
A302-300-F3
SAFETY MODEL NO.
A-300-300W
110V
AC VOLTAGE
RATED POWER
SURGE POWER
WAVEFORM
230V
110V
230V
300W
600W
OUTPUT
Modified Sine Wave
60Hz 1%
10%
FREQUENCY
50Hz 1%
60Hz 1%
10%
50Hz 1%
AC REGULATION
STANDARD RECEPTACLES TYPE-2* 2ea
TYPE-3* 1ea
TYPE-2* 2ea
TYPE-3* 1ea
LED INDICATOR
DC CURRENT
Green LED for power on; Red LED for power failure status
35A
15A
NO LOAD CURRENT DRAW 0.36A
0.2A
DC VOLTAGE
12V
24V
INPUT
VOLTAGE RANGE
EFFICIENCY (Typ.)
DC CONNECTOR
FUSE
10 ~ 15VDC
21 ~ 30VDC
85%
82%
Cigarette plug*1ea, Battery clip*1ea
Battery cord 35 A * 1, Cigarette plug 15 A* 1
Cigarette plug*1ea, Battery clip*1ea
Battery cord 20 A * 1, Cigarette plug 10 A* 1
BAT. LOW ALARM
BAT. LOW SHUTDOWN
OVER VOLTAGE
OVER TEMPERATURE
OUTPUT SHORT
BAT. POLARITY
10 0.5V
20 0.8V
19.5 0.8V
30 ~ 32V
9.5 0.5V
15 ~ 17V
45 5 / 113 9oF
PROTECTION
ENVIRONMENT
Shut-off
By fuse open
0 ~ 30 @ 100% load, 40 @ 50% load
20% ~ 90% RH non-condensing
-30 ~ +70 / -22 ~ +158oF, 10 ~ 95% RH
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
0.05% / (0 ~ 50
)
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
SAFETY & EMI CONDUCTION & RADIATION
Compliance to EN55022 class B, 72/ 245/ CEE, 95/ 54/ CE
Compliance to EN61000-4-2,3
EMS IMMUNITY
LVD
EMC
Compliance to EN60950
MTBF
200Khrs min. MIL-HDBK-217F (25
165*88*74mm (L*W*H)
)
DIMENSION
PACKING
COOLING
APPLICATIONS
1.1kg ; 16pcs / 19kg / CARTON
>100W or >40 (NTC) fan on
OTHERS
Home appliance, Power tools, Office and Portable equipment and Vehicle ...etc.
AC Output Receptacles (optional)
TYPE-1
JAPAN
TYPE-2
USA
TYPE-3
TYPE-4
TYPE-5
TYPE-6
U.K
EUROPE
UNIVERSAL
AUSTRALIA
File Name: A-301/302-300-SPEC 2007-05-14