A300ERWSeries
Low Cost, Wide Input, 3W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
Conditions
Min.
3.5
4.5
Typ.
4.0
7.0
12.0
24.0
Max.
4.5
9.0
18.0
36.0
Units
• 3W Output Power
• UL Approved (File E245422)
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
• Compact DIP Case
• Single & Dual Outputs
• Meets EN55022 Class A
• 1.0 MH MTBF
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input 16.0
Input Start Voltage
VDC
8.0
Input Filter
π (Pi) Filter (Meets EN55022 Class “A”)
1.0
1,000 1,500
Reverse Polarity Input Current
Short Circuit Input Power
Output
A
mW
Parameter
Conditions
Min.
Typ.
0.5
0.5
0.2
0.2
45
Max.
2.0
2.0
0.5
0.5
50
Units
%
%
%
%
mV P - P
mV P - P
mV rms
%
µSec
%
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Dual Output , Balanced Loads
Vin = Min to Max
• Industry Standard Pin-Out
• LOW COST!
Load Regulation
Iout = 10% to 100%
Ripple & Noise (20 MHz) (Note 1)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
General
Over Line, Load & Temp.
25% Load Step Change
100
15
120
300
2.0
0.01
500
5.0
0.02
%/ºC
Continuous (Autorecovery)
Parameter
Conditions
Min.
60 Seconds 1,500
500 VDC 1,000
100 kHz, 1V
Typ.
Max.
Units
VDC
MΩ
pF
RoHS Compliant
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
500
300
kHz
Parameter
Conditions
Min.
Typ.
+25
Max.
+71
+90
Units
ºC
ºC
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
Case
-40
-40
-40
+125
ºC
Free Air Convection
RH, Non-condensing
Humidity
95
%
RFI
Six-Side Shielded Metal Case
EN55022 Class “A”
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Conducted EMI
Physical
Case Size
Case Material
Weight
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)
Metal with Non-Conductive Base (UL94-V0)
0.42 Oz (12g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
Absolute Maximum Ratings
Parameter
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
UL 1950, EN 60950, IEC 60950
UL, cUL; File No. E245422
Conditions
Min.
Typ.
Max.
11.0
25.0
50.0
100.0
260
Units
5 VDC Input -0.7
12 VDC Input -0.7
24 VDC Input -0.7
48 VDC Input -0.7
Input Voltage Surge (1 Sec)
VDC
Lead Temperature
Internal Power Dissipation
1.5 mm From Case For 10 Sec
All Models
ºC
mW
2,500
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.