A200EHI Series
Low Cost, Miniature DIP
2W, Very High Isolation
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Key Features:
Conditions
Min.
Typ.
5.0
Max.
5.5
Units
• 2W Output Power
• 6,000 VDC Isolation
• UL Approved (File E245422)
• -40ºC to 85ºC Operation
• 24 Pin DIP Case
5 VDC Input
4.5
Input Voltage Range
VDC
12 VDC Input 10.8
Internal Capacitor
12.0
13.2
Input Filter
Short Circuit Input Power
1,500
mW
Output
Parameter
• 5V and 12V Inputs
• Single & Dual Outputs
• 16 Standard Models
• 3.5 MH MTBF
Conditions
Min.
Typ.
2.0
Max.
4.0
3.0
1.2
15
Units
%
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Dual Output , Balanced Loads
For Vin Change of 1%
Iout = 10% to 100%
1.0
%
%/%
%
• LOWEST COST!!
Load Regulation, 5V Input
Load Regulation, 12V Input
Ripple & Noise (20 MHz) (Note 1)
Output Power Protection
Temperature Coefficient
Output Short Circuit
General
Iout = 10% to 100%
10
%
100
200
mV P - P
%
120
0.03
%/ºC
Momentary (1.0 Seconds)
Parameter
Conditions
Min.
60 Seconds 6,000
500 VDC 1,000
100 kHz, 1V
Typ.
Max.
Units
VDC
MΩ
pF
RoHS Compliant
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
2
35
kHz
Conditions
Min.
Typ.
Max.
+85
Units
ºC
Operating Temperature Range
Storage Temperature Range
Cooling
Ambient
-40
-55
+125
ºC
Free Air Convection
RH, Non-condensing
Humidity
95
%
Physical
Case Size
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
1.27 x 0.62 x 0.40 Inches (32.3 x 15.7 x 10.2 mm)
Non-Conductive Black Plastic (UL94-V0)
0.42 Oz (12g)
Case Material
Weight
Reliability Specifications
Parameter
Conditions
Min.
Typ.
Max.
Units
T: (781) 344-8226
F: (781) 344-8481
MTBF
MIL HDBK 217F, 25ºC, Gnd Benign
3.5
MHours
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Safety Standards
Safety Approvals
Absolute Maximum Ratings
Parameter
UL 1950, EN 60950, IEC 60950
UL, cUL; File No. E245422
Conditions
Min.
Typ.
Max.
7.5
Units
5 VDC Input -0.7
Input Voltage Surge (1 Sec)
VDC
12 VDC Input -0.7
1.5 mm From Case For 10 Sec.
All Models
15.0
300
Lead Temperature
ºC
Internal Power Dissipation
1,500
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.